Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-00960
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/24/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
05/24/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0423-00960 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Approved with Comments Reason: Date Completed : 5/23/2023 4:51:12 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 5/17/2023 2:37:41 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 5/10/2023 6:32:19 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 5/23/2023 10:02:38 AM Electrical Review of Gas Station Retail (excludes pumps) By: Ron Ross PE E0.0 Electrical Site Plan: Need to provide exterior lumens calculation per Tucson’s requirements ie no calculation provided for the 9 N (New) wallpacks or the allowed lumen density requirements for the area illuminated. Not on Sheet Index E1.0 Power and Lighting Plan: Light switch for attic not properly connected as it also shows control for lower level cooler. Or is that the intent? Lighting Plan Keyed Notes poorly aligned. E2.0 Schedules Riser and Details: No Electrical issues E3.0 Lighting Details: Not on Sheet Index E4.0 Electrical Details: Not on Sheet Index E5.0 Electrical Specs, Legend: Not on Sheet Index Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/23/2023 7:44:18 PM First Plumbing Review: 1). The 3 compartment sink floor sink, the coffee cappuccino floor sinks, & service sink Plan page P1.0 needs to discharge thru an grease interceptor due to foods & coffee/cappuccino being prepared as shown on plan page A1.2 or provide letter from Utility authority that grease interceptor will not be required for this facility. -IPC Chapter 10 Tucson Amendments 2). Plan Page P1.0 notes 18 & 19 state gas piping is being done, none is illustrated? -IFGC 106.3.1 3). Per A1.2 Plan page P1.0 note #2 needs to be revised to include separate backflow for coffee machine -IPC 608.17.1.2 4). no water or drain shown for ice machine on plan page P1.0 as noted on A2.0 equipment schedule -IPC 106.3.1, 602.2, 802.1.3 |
||
05/23/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Site changes do not match existing DP21-0247, please resubmit matching that DP, or revise the DP. Scott Haseman scott.haseman@tucsonaz.gov |
||
05/18/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0423-00960 1306 W. Grant Rd. – I-1 General Merchandise Sales (1st Review) TRANSMITTAL DATE: May 18, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the I-1 zone (UDC 4.7.29). General Merchandise Sales is a permitted use in this zone (Table 4.8-5), subject to Use Specific Standard 4.9.13.Q. 1. The provided site plan does not match the last approved site plan DP21-0247. If you are proposing changes to the site a new DP will be required. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
05/09/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |