Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.4
Permit Number - TC-COM-0423-00945
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/28/2023 | Commercial Electrical | APPROVED | |||
| 09/28/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/26/2023 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Addition of split system AC or heat pump units to the apartments will require a heating/cooling load calculations to justify the capacities of the units being installed (Sections R403.7, IECC 2018). 2. Provide specifications for the proposed split system AC or heat pump units. The units themselves will have to comply with Sections R403.1 and R503.1.2, IECC 2018 for controls. The minimum efficiency for split system AC units is 14.3 SEER2 (capacity < 45K BTUH). The minimum efficiency for split system heat pumps is 14.3 SEER2 and 7.5 HSPF2. |
||
| 09/26/2023 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. (Note: Appendix A of Section R4-30-304, Regulatory Provisions for the Board of Technical Registration, states that signature on a seal is not to cover the registrant’s name or registration number.) 2. Clarify the scope of the proposed plumbing work (i.e. are only plumbing fixtures being replaced or is additional work proposed?). Reference: Section 107.2.1, IBC 2018. |
||
| 09/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |