Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0326-00401
Parcel: 12405023A

Address:
811 N EUCLID AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL FENCE/WALL v.1

Permit Number - TC-COM-0326-00401
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/06/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please amend the plans to indicate the height of the proposed fence. If the fence or its posts exceed 7' above the finished grade; construction drawings, design, and structural calculations prepared and sealed by an Arizona licensed design professional, will be required.
2. Please amend the plans to provide a gate detail demonstrating compliance with the accessibility provisions of ICC A117.1 (2017) and IBC Chapter 11. The detail shall include, at a minimum, the required maneuvering clearances (per Section 404.2.3), accessible hardware, and other applicable features.

For example, provide:

Maneuvering clearances at the gate, including approach direction and latch/hinge side dimensions (e.g., 60-inch minimum perpendicular clearance on the pull side with 18-inch latch-side clearance for a front approach).
Gate hardware that is operable with one hand and does not require tight grasping, pinching, or twisting, mounted between 34 inches and 48 inches above the finished surface.
Where part of the means of egress, compliant operable hardware (e.g., panic hardware where required by use and occupant load) and accessible opening forces.
Bottom rail or kick plate (where applicable) and any additional features necessary to meet accessibility and egress requirements.

Clearly dimension and label all required elements on the detail.



Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
03/31/2026 Historic REQUIRES RESUBMIT This property is located within the West UniversityHistoric Preservation Zone. Minor Historic Review is required.
SPECIAL DISTRICT SUB-RECORD: You must create a Special District (SD) Sub-Record in TDC Online for your Historic Review. For instructions on how to create a Sub-Record, see: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf.

APPLICATION REQUIREMENTS: Historic Review requires a supplemental application called a Design Package. Please see the Historic & Special Districts Application Instructions for more information about submittal requirements: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/special_districts_application_instructions_3.3.2025.pdf.
From the checklist, ensure that all requirements are submitted into the sub record as a single PDF.

Beforehand, look over fencing in the West University Design Guidelines.
This can be found and downloaded at the following web address:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation/City-Historic-Designations-and-Design-Review#section-2
04/03/2026 Site Engineering REQUIRES RESUBMIT Permit: TC-COM-0326-00401 – Commercial Fence/Wall
Location: 811 N EUCLID AV
Review Date: 4/3/2026

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-06 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.

Drainage Manual Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage…

Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete…

Overall, for application submittal requirements, see Administrative Manual Section 2-06

Site Engineering:

1. Euclid Ave is a proposed Arterial per COT Major Streets & Routes (MS&R) and the proposed alterations shown for new exterior gate at the access along Euclid Ave will require that a Development Plan be submitted and approved prior to Site Engineering approving permit TC-COM-0326-00353. The DP permit is a separate permit that can be submitted for within the “sub-records” tab of this development package permit on TDC online. For the DP permit submission, provide all construction documents similar to what was provided within this permit submission. Please show that the proposed fence/gate allows enough maneuverability for traffic access in and out of the area without impacting Euclid Ave.

If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov
04/06/2026 Site Zoning REQUIRES RESUBMIT 1. COMMENT: Provide general notes to indicate:
-Existing zoning: HC-2
-Existing use per Unified Development Code: Civic Use - Membership Organization
-Proposed height of fence as measured from design grade

2. COMMENT: Label setback distance of proposed fence from each adjacent property line in all cardinal directions.

3. COMMENT: Label setback distance from N Euclid Av property line to new proposed sliding gates.

4. COMMENT: Approval of required Special Districts (Historic) application will be required before Site Zoning can provide final approval for this permit.

Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov.
03/24/2026 PDSD Application Completeness Express REVIEW COMPLETED