Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0326-00400
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/06/2026 | Commercial Mechanical | APPROVED | |||
| 04/06/2026 | Site Zoning | APPROVED | |||
| 04/06/2026 | Water - PDSD | APPROVED | |||
| 04/02/2026 | Site Engineering | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction | PENDING ASSIGNMENT | |||
| 04/07/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please revise the plans to include the occupant load in the reception area. IBC 1004.5 Please show the reception area furniture plan. Typically we would use 15 SF per person in these areas. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 04/02/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0326-00400 (103 N PANTANO RD TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide an electrical floor plan showing all the new and existing electrical outlets, receptacles and light fixtures. 2. Show all new electrical for each of the new barber chair locations. 3. Provide a panel schedule, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. 4. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 5. Provide GFCI protection for all receptacles per NEC 210.8(B). within 6 feet of a sink. |
||
| 04/06/2026 | Commercial Plumbing | REQUIRES RESUBMIT | 1. For the use of PEX tubing, provide a branch tube sizing chart showing the correct size of PEX tubing to be used as a substitute for the copper pipe shown on the drawings. Reference: Sections 303.2 and 604.3, IPC 2024 2. Limit the temperature of the hot water to the shampoo sink to a maximum of 120 degrees Fahrenheit. The limiting device may be a thermostatic mixing valve listed to ASSE 1070, a water heater listed to either ASSE 1082 or ASSE 1084, or a temperature-actuated, flow-reduction device, ASSE 1062. Reference: Section 912.10, IPC 2024 |
||
| 03/25/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |