Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0326-00400
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/07/2026 | Commercial Building | APPROVED | |||
| 05/06/2026 | Commercial Electrical | APPROVED | |||
| 05/07/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/07/2026 | Commercial Plumbing | REQUIRES RESUBMIT | Specify how the contractor is to limit the water temperature. [Initial comment: Limit the temperature of the hot water to the shampoo sink to a maximum of 120 degrees Fahrenheit. The limiting device may be a thermostatic mixing valve listed to ASSE 1070, a water heater listed to either ASSE 1082 or ASSE 1084, or a temperature-actuated, flow-reduction device, ASSE 1062. Reference: Section 912.10, IPC 2024.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 04/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |