Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0326-00343
Parcel: 14042017C

Address:
6801 S TUCSON BL

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL REVISION v.1

Permit Number - TC-COM-0326-00343
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/08/2026 Site Zoning Standard APPROVED Interior TI
05/22/2026 Site Engineering Standard NOT REQUIRED
06/08/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/31/2026 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0326-00343
ADDRESS/PARCEL: (6801 S TUCSON BL TUCSON, AZ 85756)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
a. Submit complete plan set to address the Stop Work Order: “Stop Work Order was posted at 6801 S Tucson Blvd due to work being conducted outside the approved scope of work. Unpermitted plumbing and mechanical work was observed within the mechanical room. Inspection findings indicate the boiler was replaced with unit of insufficient size.”
b. “The contractor on file is no longer associated with the work being conducted on-site. A new licensed contractor will be required to obtain and re-issue the permit.”
c. Please resubmit.
05/28/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0326-00343 (6801 S TUCSON BL TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov


1. Submit complete plan set to address the Stop Work Order:
“Stop Work Order was posted at 6801 S Tucson Blvd due to work being conducted outside the approved scope of work. Unpermitted plumbing and mechanical work was observed within the mechanical room. Inspection findings indicate the boiler was replaced with unit of insufficient size.”

“The contractor on file is no longer associated with the work being conducted on-site. A new licensed contractor will be required to obtain and re-issue the permit.”
2. Provide updated electrical sheets to address any and all changes caused by the unpermitted mechanical and plumbing work.
06/04/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0326-00343 ()
ADDRESS/PARCEL: 6801 S TUCSON BL TUCSON, AZ 85756

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please submit complete plan set to address the Stop Work Order. “Stop Work Order was posted at 6801 S Tucson Blvd due to work being conducted outside the approved scope of work. Unpermitted plumbing and mechanical work was observed within the mechanical room. Inspection findings indicate the boiler was replaced with unit of insufficient size.”
06/04/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0326-00343 ()
ADDRESS/PARCEL: 6801 S TUCSON BL TUCSON, AZ 85756

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please submit complete plan set to address the Stop Work Order. “Stop Work Order was posted at 6801 S Tucson Blvd due to work being conducted outside the approved scope of work. Unpermitted plumbing and mechanical work was observed within the mechanical room. Inspection findings indicate the boiler was replaced with unit of insufficient size.”
a. The installation or replacement of a boiler in Arizona requires a Certificate Inspection from the Industrial Commission of Arizona. The City of Tucson will provide a permit for the installation of the utilities that support the boiler (e.g. fuel, power, drains, etc.) but the installation, clearances, and special egress requirements for the boiler itself are controlled by the Industrial Commission of Arizona.

You can start the process of obtaining a Certificate Inspection process by going to

https://www.azica.gov/forms/adosh-boiler-boiler-and-pressure-vessel-new-install-reinstall-form
05/28/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Outdoor Lighting Review TC-COM-0326-00343 (6801 S TUCSON BL TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Please note on the plans that the replacement lighting fixtures shall be full-cutoff, with a maximum color temperature of 3500K, OLC 402.1.
06/04/2026 Water - PDSD Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0326-00343 ()
ADDRESS/PARCEL: 6801 S TUCSON BL TUCSON, AZ 85756

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please submit complete plan set to address the Stop Work Order. “Stop Work Order was posted at 6801 S Tucson Blvd due to work being conducted outside the approved scope of work. Unpermitted plumbing and mechanical work was observed within the mechanical room. Inspection findings indicate the boiler was replaced with unit of insufficient size.”
06/06/2026 Fire New Construction Standard REVIEW COMPLETED
05/18/2026 PDSD Application Completeness Express REVIEW COMPLETED