03/17/2026 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0326-00316
ADDRESS/PARCEL: (2445 N ORACLE RD TUCSON, AZ 85705)

Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. ATTACHMENTS
a. Three points of connection vertically are shown on the drawing.
i. Additional points of connection would secure the entire sign.
ii. Please add more attachments horizontally.
b. The type of attachment used may not be sufficient for this adobe brick.
i. This type of wall material are not ideally strong to support such an awning.
ii. Please propose a bolt that encompass the entire thickness of the wall with a structural member on the backside linking all bolts together.
2. Please resubmit.
03/16/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical & Outdoor Lighting Review TC-COM-0326-00316 (2445 N ORACLE RD TUCSON, AZ 85705)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

Commercial Electrical Review:
1. Provide the electrical load/amperage of the new lighting fixtures and show that a single 20A circuit is sufficient.

Outdoor Lighting Review:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf


1. The addition of the two new neon lighting fixtures requires compliance with the City of Tucson Outdoor Lighting Code. These lighting fixtures do not appear to meet the requirements found in chapter 5 of the OLC for internally illuminated sings and must meet all requirements of the OLC.
2. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan, both new and existing. Number the light fixtures on your lighting fixture table and use the same number on your site plan.
3. List the Lighting Area per OLC (typically E3) chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1.
4. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation.
5. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4.
6. Show lamps with a maximum of 3500K color temperature, OLC 402.1.
7. Provide the manufacturer’s specification sheets for the outdoor lighting fixtures. Include the lumen and color temperature values for each outdoor fixture type.
8. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2.

https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf

9. Specify any exceptions used.

10. Provide Curfew lighting controls If applicable Per section 403.
03/16/2026 Site Zoning REQUIRES RESUBMIT Site Zoning cannot approve until historic approves.
03/05/2026 PDSD Application Completeness Express REVIEW COMPLETED