Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0325-00637
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/18/2025 | Commercial Building | APPROVED | |||
| 04/03/2025 | Commercial Electrical | NOT REQUIRED | No modifications to the existing electrical. | ||
| 04/03/2025 | Outdoor Lighting | NOT REQUIRED | No modifications to the existing outdoor lighting. | ||
| 04/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/03/2025 | Site Engineering | PENDING ASSIGNMENT | |||
| 04/21/2025 | Signs | REQUIRES RESUBMIT | April 19. 2025 1125 S. Swan Rd - Activity # TC-COM-0325-00637 - Billboard COT 307 maintenance Comments: 1. The Scope of Work to Replace Trim includes the complete removal of the 10 pieces (per face) of the Metal Face Panels. The Scope explains how the panels must be removed in order to access and replace the plywood trim and wood stringers and then the panels would be reinstalled. Trim and Stringers are allowed to be replaced with like materials. 2. However, the text of the Scope of Work and a Detail in the lower right corner of Sheet 2 titled "Face Panel Attachment (Top View)," shows an existing connection of a Panel to a Stringer using "Obsolete panel section clips 0.188" thick to be removed and not reinstalled (35 pcs.)". A 16d nail is shown in the Detail as somehow connecting the metal panel to the obsolete clip, but how that actually works is not clear at all. What is the existing 16d nail secured to? 3. Details A and B on Sheet 2 are not consistent in identifying exactly where and how the metal panels are proposed to be attached to the new stringers with spacers. Detail A is missing the metal panel altogether. The proposed alternate attachment detail is not shown, but the Scope notes, "Reinstall existing (10 pcs.) 29"x 10'-6"x .03" vertical metal face panels with 1" depth of outside perimeter attaching with new (like) 16d nails." So, potentially, this doesn't match the requirement in Exhibit 9 for "like" materials utilized in the same manner as the existing. Please provide a clearer detail showing what is existing at the top and bottom of the metal panels and how the new 16d nails are proposed to secure the metal panels to the new stringers in a "like" manner if the obsolete clip is removed and not replaced. 4. In the drawing on Sheet 2 titled "Poster Panel Top View," exactly what is being attached to the tapered I-beams is not identified. I suspect it is a stringer, not a metal panel. Please clarify. 5. Please revise and resubmit the requested details. Kathi McLaughlin, BRC Reviewer |
||
| 04/22/2025 | Site Zoning | REQUIRES RESUBMIT | Until approved by Signs Zoning cannot approve this permit. | ||
| 04/03/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 04/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |