Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0325-00600
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2025 | Commercial Electrical Standard | APPROVED | |||
| 04/21/2025 | Commercial Mechanical Standard | APPROVED | |||
| 04/21/2025 | Commercial Plumbing Standard | APPROVED | |||
| 04/18/2025 | Site Zoning Standard | APPROVED | |||
| 04/21/2025 | Water - PDSD Standard | APPROVED | |||
| 04/03/2025 | Outdoor Lighting Standard | NOT REQUIRED | No changes to outdoor lighting. | ||
| 04/18/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 04/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/21/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please amend the plans to indicate the following information to be used in completing the C of O information. IBC 107.2.1 A. Are Fire sprinklers provided? B. Please provide the square footage of the TI? 1st and 2nd Floors? 6400 SF or? C. What is the total square footage of the occupied space. 6400 SF? 2. Sheet A5: Please amend the plans to remove the NOT FOR CONSTRUCTION annotation. IBC 107.2.1 3. Sheet A5: Please amend the interior elevations to show the grab bars shall be installed in a horizontal position, 33 inches minimum and 36 inches maximum above the floor measured to the top of the gripping surface, and not to the center of the grab bar. 2009 ICC A117.1 609.4.1 3. Sheet A5: Please amend the interior elevations to show height of water closet seats shall be 17 inches minimum and 19 inches maximum above the floor, measured to the top of the seat. 2009 ICC A117.1 604.4 4. Sheet A5: Please amend the plans to provide a plan view drawing of the water closet showing the centerline of the water closet 16 inches minimum and 18 inches maximum from the side wall or partition. 2009 ICC A117.1 604.2 5. Please indicate a special inspection on the plans to verify the recommendations 1-3 described in the Structural Engineer’s letter on page 3 of the Structural Calculations. IBC 1075.1 6. Please provide the special inspection certificate with Part A, and Part B, completed with next submittal. IBC 107.2.1 https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 04/10/2025 | Fire New Construction Standard | REVIEW COMPLETED | 1.Any fire alarm or fire sprinklers alteration requires a separate permit. 2. Fire extinguishers installations shall comply with Section 906 of the 2024 International Fire Code. |
||
| 03/27/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |