Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0325-00583
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/11/2025 | Outdoor Lighting Standard | APPROVED | |||
| 04/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/07/2025 | Commercial Building Standard | REQUIRES RESUBMIT | For questions contact ekulik@willdan.com 480.241.0634. 1. Sheet ARQ-1 Septic not part of this review. 2. Sheet ARQ-3 Provide ES Report for roofing material. 3. Sheet ARQ-6 3000psi concrete requires special inspection. Obtain Form from the County. 4. Sheet ARQ-6 Water truck rolling is not an approved method for compaction. Identify an approved method for obtaining proper compaction. 5. ARQ-7 Provide roof ventilation calculations per IRC R806. |
||
| 04/07/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | 1. Sheet ARQ-5 Provide a one-line diagram for SES. (grounding electrode) | ||
| 04/07/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | 1. Sheet ARQ-8 Verify exhaust fan is approved for the location over the shower. Provide model # and cut sheets. | ||
| 04/07/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Sheet ARQ-4 Provide Gas Line sizing per IRC G2413. | ||
| 04/17/2025 | Site Engineering Standard | REQUIRES RESUBMIT | TC-COM-0325-00583 2401 S WILMOT RD The building permit cannot be approved until the associated development package, TD-DEV-0125-00016, is approved. Per UDC Article 3.3.3.7.a The approved site plan (Development Package) on file with the PDSD is the basis for issuance of building permits. Chris Arrington chris.arrington@tucsonaz.gov |
||
| 04/15/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0325-00583 2401 S WILMOT RD. - C-2 Educational Use: Elementary and Secondary (1st Review) TRANSMITTAL DATE: ‎April 15, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Educational Use: Elementary and Secondary is an approved use in the zone (UDC Table 4.8-4), subject to Use Specific Standard 4.9.3.D.1 - 7. 1. Zoning acknowledges the Charter School Exemption Letter dated 04/30/2013 for this site but until development package TD-DEV-0125-00016 has been approved by all other review agencies Zone will not pass the Zoning review for this building permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/17/2025 | Water - PDSD Standard | REQUIRES RESUBMIT | Only half of each plumbing drawings is visible. | ||
| 04/16/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 03/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |