Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0325-00530
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2025 | Site Zoning Standard | APPROVED | |||
| 04/11/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 04/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/16/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0325-00530 ADDRESS/PARCEL: (3255 S WILMOT RD Unit:UNIT 101 TUCSON, AZ 85730) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. NOTE: On 4/16/25 the City of Tucson spoke with Andre Plaisted of A&D Designs llc regarding the Manua J. Mr. Plaisted informed the city that he is not familiar with such a document and provided Mike’s phone number from Goodfellas Air Conditioning Inc. to obtain such an information. 2. On 4/16/25, we called and spoke with Mike regarding the following: a. The Manual J was submitted as part of the submittal. Within the Design Information page, it identifies the required Sensible Cooling as 12,930 Btuh. b. The Manual S was also submitted. It identifies the chosen manufacturer as GE and Model being AJHQ08AWH. i. However, it indicates the Sensible capacity of the unit as 0 Btuh. ii. It indicates the Latent capacity of the unit as 0 Btuh. iii. It indicates the Total Capacity of the unit as 0 Btuh. iv. Therefore, the City of Tucson cannot approve this building permit since the unit capacity is not provided. c. NOTE: Mike indicated during our phone conversation that he will call back and will provide the required information. This did not occur. d. Please submit the Extended Rating Table information on the chosen unit. This will allow the city to ascertain whether the chosen unit will provide the required heating and cooling. 3. Please resubmit. Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 04/16/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0325-00530 ADDRESS/PARCEL: (3255 S WILMOT RD Unit:UNIT 101 TUCSON, AZ 85730) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. NOTE: On 4/16/25 the City of Tucson spoke with Andre Plaisted of A&D Designs llc regarding the Manua J. Mr. Plaisted informed the city that he is not familiar with such a document and provided Mike’s phone number from Goodfellas Air Conditioning Inc. to obtain such an information. 2. On 4/16/25, we called and spoke with Mike regarding the following: a. The Manual J was submitted as part of the submittal. Within the Design Information page, it identifies the required Sensible Cooling as 12,930 Btuh. b. The Manual S was also submitted. It identifies the chosen manufacturer as GE and Model being AJHQ08AWH. i. However, it indicates the Sensible capacity of the unit as 0 Btuh. ii. It indicates the Latent capacity of the unit as 0 Btuh. iii. It indicates the Total Capacity of the unit as 0 Btuh. iv. Therefore, the City of Tucson cannot approve this building permit since the unit capacity is not provided. c. NOTE: Mike indicated during our phone conversation that he will call back and will provide the required information. This did not occur. d. Please submit the Extended Rating Table information on the chosen unit. This will allow the city to ascertain whether the chosen unit will provide the required heating and cooling. 3. Please resubmit. Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 03/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |