Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0325-00503
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/08/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 9/3/2025 11:40:48 AM 1. (UNRESOLVED) - General - No Mechanical Plans Submitted. i. No Mechanical Plans Submitted for 2330 E BROADWAY BLVD. Provide Minimum Mechanical Design Criteria. Provide Mechanical Plans. Show (what applies) all existing to stay, existing to be relocated, existing to be removed, and new Supply, Return, and Exhaust duct work. Show termination point on all exhaust duct work and O/A. - 2018 IECC Section C103.2Information on construction documents - 2018 IBC – Section [A]107.2.1Information on construction documents. a. No Mechanical plans submitted for Bldg. 2330. - 2018 IECC Section C103.2Information on construction documents - 2018 IBC – Section [A]107.2.1Information on construction documents. |
||
| 09/08/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/6/2025 6:23:56 PM THIRD Plumbing Review::Comment 2 remains RESOLVED 1). Plan Page P102.1: Gas load calculations missing sizing table used & gas system legnth. Add sizing table used & gas system legnth to gas load calcs. -2018 IFGC 402.3 Un-RESOLVED 2). Plan Page A301: Missing lavatory to lavatory center separation distances. Add lavatory to lavatory center separation distances. -2018 IPC 405.3. **Detail #1 shows 6ft 11 inches for the overall triple lavatory space, 3 fixtures would need a minimum of 90" inches finished to maintain 15" sidewall & 30" fixture to fixture separation** |
||
| 09/15/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0325-00503 Location: 2330 E BROADWAY BL Review Date: 9/15/2025 Site Engineering Comments: 1. Site Engineering will be unable to approve permit TC-COM-0325-00503 until the associated development package TD-DEV-1124-00315 is approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 09/16/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0325-00503 and TC-COM-0325-00504 – Stravenue Social 2330 E. Broadway Blvd. Tucson, AZ 85719 Tenant Improvement; Remodel interior of existing west building shell (2nd Review) TRANSMITTAL DATE: 9/16/2025 DUE DATE: 9/18/2025 This site is located in the C-1 zone (UDC 4.7.20). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has conducted a cursory review of the building permit plan set and while it appears the site plan is consistent with the development package, zoning cannot approve the building permit plan set until the associated development package (TD-DEV-1124-00315) has been approved by all reviewers. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 08/27/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |