Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2025 Commercial Building APPROVED
05/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/01/2025 Commercial Plumbing REQUIRES RESUBMIT Replacement faucets for lavatories shall be metering faucets. The metering faucets shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.11, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09 [Initial comment: Provide a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.]
04/18/2025 PDSD Application Completeness Express REVIEW COMPLETED