Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0325-00481
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/21/2025 | Commercial Building | APPROVED | |||
| 04/21/2025 | Commercial Mechanical | APPROVED | |||
| 04/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/14/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0325-00481 (1141 N EL DORADO PL Unit:BLDG 3 UNIT 200 TUCSON, AZ 85715) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. >> Electrical sheets are not sealed by an Arizona registered design professional. The Electrical Sheets are still not sealed. 3. Sheet E3.0, Keyed Notes #1 shows an Available Fault Current of 75,000 Amps, while the equipment is rated for 65,000 AIC. Provide the actual Available Fault Current from TEP for this location or provide updated equipment rated for the 75,000 Amp fault current. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/21/2025 | Commercial Plumbing | REQUIRES RESUBMIT | Comment not resolved. The full open valve is to installed on the discharge side of the check valve to allow the check valve to be repaired or replaced without causing a flood. The valve shown on the revised detail is not required. [Initial comment: Revise detail 1/P01 to provide a full-open valve on the discharge side of the check valve. Reference: Section 712.2, IPC 2018.] | ||
| 04/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |