Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0325-00478
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/03/2025 | Commercial Building Standard | APPROVED | |||
| 03/28/2025 | Site Zoning Standard | APPROVED | |||
| 04/03/2025 | Water - PDSD Standard | APPROVED | |||
| 04/03/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/20/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0325-00478 (3232 N CAMPBELL AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide new and updated panel schedules, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 2. Designate the circuit number, that corresponds to the panel schedule, at the location of each new or modified light fixture, receptacle, appliance, and equipment disconnect switch, NEC arts;300 and 408.4. 3. Provide electrical load calculations, for the Main Service Panel and any Sub-panels, Per NEC 220.40. 4. A signature and date are required as part of the Registrant Seal (Electrical). Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that in addition to signing the seal, the registrant shall include the date the document was sealed. >>>The Seal is missing the date signed. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/03/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Sections C403.1.1 and C502.2.3, IECC 2018. | ||
| 04/03/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Show the location of the cleanouts in the proposed additions to the grease waste piping. Reference: Section 708.1, IPC 2018. | ||
| 03/20/2025 | Fire New Construction Standard | REVIEW COMPLETED | Fire Alarm upgrades will required a separate permit. | ||
| 03/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |