Permit Number: TC-COM-0325-00463
Parcel: 116170470

Address:
750 N GRANDE AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0325-00463
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/17/2025 Commercial Plumbing Fast REQUIRES RESUBMIT 1. Show the water supply to the new mop sink and the location of the water heater. Reference: Section 107.2.1, IBC 2018.
2. Show how the mop sink and floor drain are connected to the building drainage system. Section 107.2.1, IBC 2018.
3. Show the locations of the required cleanouts. Section 708.1, IPC 2018
4. Show how the new mop sink is be vented Reference: Section 901.2.1, IPC 2018.
03/10/2025 PDSD Application Completeness Express REVIEW COMPLETED