Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0325-00430
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/17/2025 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the Outdoor Lighting. | ||
| 05/02/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/02/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0325-00430 ADDRESS/PARCEL: (8080 S HOUGHTON RD TUCSON, AZ 85747) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. The Electrical engineer sealing the Photovoltaic System sheets is Jeffrey H. Ansley of Arizona date signed 6/15/18 (not acceptable). Please have Mr. Ansley affix his seal/signature in the year 2025. 2. The structural calculations is sealed by structural engineer Madhan Kumar Kantha Samy of Arizona. a. 59 pages of 95 total pages have the stamp, “NOT APPROVED FOR CONSTRUCTION”. b. The City of Tucson cannot review and approve a set of submittals bearing such a stamp. c. Please remove it. 3. The General Structural Notes sheet. a. Is calling for special inspection on: i. Field Welding ii. Structural Steel iii. Masonry Construction iv. Post-Installed Epoxy Anchor b. The sheet is sealed by a Daniel Joseph Steele whose license expired on 12/31/21. c. This structural sheet seems to have come from an Interior Renovation of the Fry store. d. Please have structural engineer Madhan Kumar Kantha Samy provide the appropriate General Structural Notes sheet that is generated for this Photovoltaic System. i. Please have Mr. Samy of Arizona seal/sign/date the sheet. 4. Load Testing/Laboratory Report a. Page 30 is sealed/signed by an Engineer Robert Nieminen with a Florida License. b. The Florida license is now allowed in Arizona. c. Please have Structural Engineer Madhan Kumar Kantha Samy of Arizona review this report and have him seal/sign/date the report. 5. Construction Plans: 59 pages of 113 total pages have the stamp, “NOT APPROVED FOR CONSTRUCTION”. a. The City of Tucson cannot review and approve a set of submittals bearing such a stamp. b. Please remove it. 6. Please re-submit If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 04/22/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0325-00430 (8080 S HOUGHTON RD TUCSON, AZ 85747) 2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. The Registrant Seal for electrical is dated from 2018 and is not valid. Please have EOR Seal properly seal the required pages. 3. Provide complete Rapid Shutdown: 690.12 Rapid Shutdown of PV Systems on Buildings. PV system circuits installed on or in buildings shall include a rapid shutdown function to reduce shock hazard for emergency responders in accordance with 690.12(A) through (D). 4. The (2 sets) #350KCMIL CU conductor appears undersized for the given 700A OCPD. Conductors shall be protected with OCPD’s having a rating not exceeding the allowable ampacity of the conductor, reference NEC 310.15, 240.4. Reference sheet E400, conductors ACDS-1 – MSB. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |