Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0324-00567
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2024 | Commercial Electrical | APPROVED | |||
| 04/17/2024 | Commercial Mechanical | APPROVED | |||
| 04/16/2024 | Site Zoning | APPROVED | |||
| 04/17/2024 | Water - PDSD | APPROVED | |||
| 04/16/2024 | Site Engineering | NOT REQUIRED | |||
| 04/17/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/16/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0324-00567 ADDRESS/PARCEL: (15 S HARRISON RD TUCSON, AZ 85748) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Egress through intervening spaces. IBC 1016.2 a. 2. Means of egress are not prohibited through stockrooms in Group M occupancies where all of the following are met: b. 2.1.The stock is of the same hazard classification as that found in the main retail area. c. 2.2.Not more than 50 percent of the exit access is through the stockroom. d. 2.3.The stockroom is not subject to locking from the egress side. e. 2.4.There is a demarcated, minimum 44-inch-wide aisle defined by full- or partial-height fixed walls or similar construction that will maintain the required width and lead directly from the retail area to the exit without obstructions. 2. Ensure that the facility is accessible complying to the ICC/ANSI A117.1 for both Employees and Customers internally as well as accessible route from drop off to front door. Provide drawings that illustrate the ANSI accessible counter at the cashier in both height and width requirements. 3. The sink in Restroom is infringing into the required floor clearance area of 60” x 56” at the water closet. Other fixtures not allowed within the required clear area. Please relocated the sink complying to the ANSI accessible requirement per ICC ANSI A117.1 figure 604.3 9. 4. Complete your Code Analysis including confirming whether a Fire Sprinkler is present, the number of handicap parking stalls 5. Please resubmit. |
||
| 04/17/2024 | Commercial Plumbing | REQUIRES RESUBMIT | The wall-mounted lavatory entry on the Plumbing Fixture Schedule (MP1.0) refers to a restroom upgrade. If this upgrade is to be part of this activity, show that the lavatory will comply with Sections 416.5, 419.6 (as amended by the City of Tucson), 606.4, 607.1.2, IPC 2018, and Section C404.5, IECC 2018. | ||
| 04/01/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 04/01/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |