Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0324-00516
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/20/2024 | Commercial Electrical | APPROVED | |||
05/20/2024 | Site Zoning | APPROVED | |||
05/17/2024 | Site Engineering | NOT REQUIRED | |||
05/21/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/21/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0324-00516 ADDRESS/PARCEL: (3470 S KINO PW Unit:UNIT 120 TUCSON, AZ 85713) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Sheet A01: The Vicinity Map is not correct. Please provide the correct site that is of Tucson, Arizona (not from California). 2. Sheet A01: Please remove any code notes referring to California Code, San Diego Code, etc. 3. Please submit a demolition plan. 4. Sheet A01: Please complete the code analysis to include the occupant load calculation from each space function, minimum plumbing requirement calculation/what is required/what is provided, provide the interior wall and ceiling finish requirements by occupancy per IBC Table 803.13, add 2018 International Building Code and City of Tucson local Amendments, add ICC ANSI A117.1 - 2009 Accessible and Usable Buildings and Facilities 5. Sheet A01: Automatic sprinkler system exist per previous permit, please clarify and correct this. 6. Sheet A05: At water closet, show the 60" W x 56" D clearance area on the floor per ANSI A117 Figure 604.3 Ensure no other fixtures are within this area. provide drawings illustrating the required ANSI A117 counter height and surface width for the reception with callout 1 and the counter with callout 2 7. Sheet A06: Submit a wall section drawing of the following: Tenant separation using fire partition with fire-resistance rating of not less than 1 hour per IBC 402.4.2.1 and IBC 708 extend from the top of the foundation or floor/ceiling assembly below to the underside of the floor or roof sheathing, deck or slab above shall have penetration complying to IBC 714 and joints complying with IBC 715 protected by an approved fire-resistant joint system to resist the passage of fire for a time period not less than the required fire-resistance rating of the wall, floor or roof in or between which the system is installed. 8. Locate/label the lighted exit signs and emergency lights with back up battery power as well as the fire extinguisher. 9. Please resubmit. |
||
05/21/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. The controlling codes for mechanical work done in the City of Tucson are the 2018 International Building Code, the 2018 International Mechanical Code and the 2018 International Energy Compliance Code. Revise the general notes on M01 by referring to the correct codes. 2. The Existing RTU Schedule, M01, shows two existing heat pumps. Is this correct? If so, show the location of the unused heat pump on the roof plan. Reference: Section 107.2.1, IBC 2018. 3. Show the size, routing, and termination of the condensate drains from the existing heat pump(s). Reference: Section 307.2.1, IMC 2018 as amended by the City of Tucson. 4. Footnote b on Table 403.3.1.1, IMC 2018 states that mechanical exhaust is required for the nail salon and no air from the nail salon may be recirculated to any other space. With a single heat pump serving the suite, the entire suite must be ventilated as a nail salon (i.e. include the reception, break, facial, and hallway areas as nail salon). Reference: Section 403.2.1 (3), IMC 2018. 5. Nail salons require a source-capture exhaust system for each manicure and pedicure station. The exhaust inlets shall be located a maximum of 12” horizontally and 12” vertically from the point of chemical application. Provide details showing how this is to be accomplished. Reference: Table 403.3.1.1, footnote h and Section 502.20, IMC 2018. 6. The occupant load used to calculate the required ventilation is not necessarily the same as the occupant load used for calculating exiting requirements. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3.1.1, IMC 2018 or an approved engineering analysis of the specific occupancy type. Reference: Section 403.3.1.1, IMC 2018. 7. Revise the Air Balance Calculation using the results of the revised ventilation calculations and only the proposed equipment (e.g. do not include a non-existent make up air unit). Reference: Section 107.2.1, IBC 2018 and Section 501.4, IMC 2018. |
||
05/20/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Verify that the specified Crane lavatory is available and still listed. Reference: Sections 303.4 and 402, IPC 2018. 2. Specify that all proposed plumbing fixtures shall be listed by a third-party certification agency as complying with the relevant standards. Reference: Section 303.4, IPC 2018. 3. Provide a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 4. Pedicure chairs shall have hot water limited to a maximum temperature of 120 degrees Fahrenheit using a device conforming to ASSE 1070. Reference: Section 423.3, IPC 2018, as amended by the City of Tucson. 5. Provide a detail of the specified pedicure chairs that shows that the installation complies with the requirements of Section 423.3, IPC 2018, as amended by the City of Tucson (e.g. backflow protection, drainage, etc.). 6. The developed length of the hot water supply piping appears to be greater than fifty feet; provide a method for maintaining the temperature of the hot water supply system. Reference: Section 607.2, IPC 2018 and C404.5, IECC 2018. 7. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. 8. Provide automatic or manual controls for the circulating hot water system per Section C404.6, IECC 2018. 9. The scheduled clothes dryer on sheet M01 is natural gas-fired. Provide a design for the natural gas piping system. Reference: Section 401.1, IFGC 2018. |
||
05/20/2024 | Water - PDSD | REQUIRES RESUBMIT | Provide the size of the water meter serving this suite, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018. | ||
05/13/2024 | Fire New Construction | REVIEW COMPLETED | |||
05/07/2024 | PDSD Application Completeness | REVIEW COMPLETED |