Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0324-00474
Parcel: 130144220

Review Status: Requires Resubmit

Review Details: COMMERCIAL FENCE/WALL v.1

Permit Number - TC-COM-0324-00474
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/05/2024 Commercial Building APPROVED
04/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/04/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0324-00474
1502 S COLUMBUS BL – R-3
Perimeter Wall ( 1st Review)

TRANSMITTAL: April 4, 2024
This site is located in the R-3 zone (UDC 4.7.12). A multifamily, condominiums, is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf.

2. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .)
1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron;
2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall;
3. A greater height is required through the rezoning process or the special exception land use process; or,
4. A greater height is required by a specific UDC standard.
As the proposed wall as shown on the plan does not meet any of the exceptions a Design Development Option (DDO) must be submitted and approved for wall height. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.


If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/21/2024 PDSD Application Completeness Express REVIEW COMPLETED