Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0324-00451
Parcel: 11207271A

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.4

Permit Number - TC-COM-0324-00451
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2024 Commercial Plumbing REQUIRES RESUBMIT A flowrate of 52 GPM will result in a water velocity of 8 feet per second, a 60-80 GPM demand will require the use of 2.5” PEX to limit the water velocity to 8 feet per second. Reference: Section 303.2, IPC 2018. [Third comment: Comment not addressed. Provide the water demand that the relocated 1-1/2” water meter will be serving.] [Second comment: A 1-1/2” water meter is allowed to serve a demand of up to 100 GPM which would result in an excessive water velocity for a 1-1/2” PEX water line. Provide the water demand that the relocated 1-1/2” water meter will be serving.] [Initial comment: Provide the water demand that the relocated 1-1/2” water meter will be serving. The submitted information states that the water service pipe will be 1” PEX. Reference Section 107.2.1, IBC 2018.]
05/29/2024 PDSD Application Completeness Express REVIEW COMPLETED