Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0323-00906
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/03/2023 | Site Zoning | APPROVED | |||
04/19/2023 | Site Engineering | NOT REQUIRED | |||
04/19/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/19/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0323-00906 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditinally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Denied E-120 SECOND FLOOR DEMOLITION PLAN: Could not locate Keynote #5. E-310 FIRST FLOOR POWER PLAN: Need to provide an interior lighting Comcheck to show IECC compliance. E-602 PANEL SCHEDULES: 125-amp Bus rating for LP1 section 2 is not sufficient for panel. Needs to be fully rated at 400 amps when connected with feed thru lugs. As Panel LP1 is new, it also needs to call out the minimum KAIC rating required. PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: 1). The replaced high/low drinking fountain location on plan page P-210 doesn't correlate with plan pages A-031 & A-210. Plan pages need to correlate -IPC 106.3.1 ( If drinking is relocating show plumbing illustrations) 2). Illustrate High/Low drinking fountain same as A-031 & A-210 - IPC 410.3 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
04/14/2023 | Fire New Construction | REVIEW COMPLETED | |||
04/03/2023 | PDSD Application Completeness | REVIEW COMPLETED |