Permit Number: TC-COM-0323-00862
Parcel: 116022300

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0323-00862
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2023 Site Zoning APPROVED
08/18/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
08/18/2023 Commercial Plumbing REQUIRES RESUBMIT Submit your fire sprinkler and fire alarm drawings to Tucson Fire Department for review and approval.
08/18/2023 Commercial Structural REQUIRES RESUBMIT With the Zoning Department, ensure that you process the Request for Zoning Authority Clearance & submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. NOTE: R-4 maximum allowable is 10 clients (Indicate the Occupancy Classification, the number of clients on your drawings as well as indicate that it is Behavioral Health facility & a custodial care Condition 1 per IBC 310 (this will determine the type of fire sprinkler system the fire department will require). NOTE: Submit a complete Egress Plan. 1.) not used 2.) no used 3.) not used 4.) Show/locate the side & back grab bars at the Water Closet as well as at the Shower, make sure to indicate the installation of Structural Backer Board for these grab bars per IBC Chapter 11. 5.) not used 6.) Fire Sprinkler is required per IBC 420 and processed as a separate permit. Submit the drawings to Tucson Fire Department for review and approval. They will conduct fire inspection, the inspection approval document will be required before issuing the Certificate of Occupancy. 7.) A fire alarm is required [IBC 907], If they exist...indicate them on your drawing. If not...please propose to install them. Illumination with emergency backup power is required in all components of the means of egress system [IBC 1008]. Please locate those equipments on your plan (to be inspected by Tucson Fire Department). Electrical work (conductors/wiring/breaker ONLY) related to the installation of Emergency Lights, Lighted Signs, Fire/Audible/Smoke Alarms/Fire Extinguisher will be inspected by City of Tucson inspectors, show on your plans so that our inspectors will know what wiring/breaker to inspect and shall also be reviewed as part of this permit. Any new renovation work must be included as part of this building permit. 8.) A Final inspection will be conducted by our inspectors prior to issuance of the Certificate of Occupancy. 9.) An Operator's License must be applied for with the State, the absence of this license shall void this building permit. 10.) Submit a draft copy of the State License application confirming the exact use title for the certificate of occupancy document. 11.) If you have any questions, contact Justin Eder at Justin.Eder@tucsonaz.gov or at 520-837-4976.
07/19/2023 PDSD Application Completeness REVIEW COMPLETED