Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0323-00831
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/20/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/06/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0323-00831 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide Structural Calculations for Foundations per Section 1601.1 of International Building Code 2018. 2. Provide Wind Load Calculations for the Building per Section 1609 of International Building Code 2018. 3. Provide Seismic Calculations for the Building per Section 1613 of International Building Code 2018. 4. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. 5. DEFERRED SUBMITTAL REQUIREMENTS Structural general notes are to include any components of the building that may be considered deferred submittals. IBC Section 107.3.4.1 requires deferred submittals to be approved by the building official. If items will be deferred the plans are to clearly note the following per IBC Section 107.3.4.1: * To be reviewed by design professional in responsible charge. * Design professional shall affix a notation that the deferred items are in general conformance with their design of the building. * They shall be submitted for review by the building official. * Shall not be installed until approved by building official. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. BUILDING REVIEW COMMENTS: Denied 1. General: A minimum number of self-storage facilities are required to have mobility features. Provide a room matrix that shows the accessible unit calculations. Additionally, ensure that rooms are properly dispersed throughout the structure. Section 225.3 and 225.3.1 of the 2010 ADAAG. 2. General: Provide an architectural site plan. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E3.0: Could not locate Key Note 4. PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: 1). Provide roof/metal Bldg plans that illustrate the roof drainage methods, -IPC 1101.2 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
04/20/2023 | Fire New Construction | REQUIRES RESUBMIT | Address building review comments. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
||
04/14/2023 | Site Engineering | REQUIRES RESUBMIT | The permit cannot be approved until its associated development package, DP21-0093, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
04/17/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0323-00831 1333 South Pantano Parkway – C-3 Self-storage expansion (1st Review) TRANSMITTAL DATE: April 17, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Combine all construction documents (cover sheet, civil, architectural, etc., etc.) into a single PDF. 2. Per Tucson Unified Development Code (UDC) Section 3.3.3.G.2.c, a development package is required for new buildings and structures on non-residential development. The development package is a separate submittal and shall meet the requirements of Administrative Manual Section 2-06.0.0. Active DP21-0093 for new recreational vehicle canopies on this site shall either be revised to include this permit’s scope of work or withdrawn to allow a new development package submittal for this permit’s scope of work. If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
03/23/2023 | PDSD Application Completeness | REVIEW COMPLETED |