Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0323-00805
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/31/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/31/2023 | Commercial Structural | REQUIRES RESUBMIT | BUILDING REVIEW: Assuming that you are able to resolve the zoning issues with the Zoning Department, ensure you obtain approval on the Request for Zoning Authority Clearance. NOTE: R-3 maximum allowable is 5 clients & R-4 maximum allowable is 10 clients (Indicate the Occupancy Classification, the number of clients on your drawings as well as indicate whether it is Group Home, Behavioral Health, Assisted Living, Day Care, etc.). Include a statement as part of your code analysis as to how the facility handles any persons receiving custodial care who require limited verbal or physical assistance responding to an emergency situation to complete building evacuation and self preservation. 1. On the Site Plan show/indicate the Accessible route from drop off location to the entry door complying to ANSI A117. In an Emergency, show/locate the gathering area where it is safe from danger IBC 310.5. 2. Indicate the clear opening of the doors complying to ANSI A117. 3. Indicate the clear width of hallways. 4. Show/locate the two grab bars at the Water Closet as well as the two grab bars at the Shower, make sure to indicate the installation of Structural Backer Board for these grab bars. 5. Provide Emergency Escape & Rescue Openings per IRC R310 at every bedroom/sleeping space. On the drawing adjacent to the opening(s), indicate the clear opening for both horizontally and vertically and provide the dimension from the finish floor to the bottom of the opening. Indicate if there are obstacles on either side of the opening. 6. Fire Sprinkler is required and processed as a separate permit. Submit the drawings to the Fire Department for review and approval. They will conduct fire inspection, their approval will be required before issuing the Certificate of Occupancy. 7. Electrical work (conductors/wiring/breaker ONLY) related to the installation of Emergency Lights, Lighted Signs, Audible Fire/Smoke Alarms shall also be reviewed as part of this permit & will be inspected by City of Tucson inspectors. Any new renovation work must be included as part of this building permit. 8. A Final inspection will be conducted by our inspectors prior to issuance of the Certificate of Occupancy. 9. An Operator's License must be applied for with the State, the absence of this license shall void this building permit. 10. Submit a copy of the State License application as part of this permit. 11. If you have any questions, contact Justin Eder at Justin.Eder@tucsonaz.gov or at 520-837-4976. | ||
| 05/12/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-0323-00805 3456 East 27th Street – R-2 Sober living facility (1st Review) TRANSMITTAL DATE: May 12, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. A “sober living facility” is not a land use type defined within the Tucson Unified Development Center (UDC). Review UDC 11.3.7.D and provide a Residential Care Services land use type on the site plan that corresponds with the proposed facility. 2. Per UDC 7.4.4-1, four on-site motor vehicle parking spaces are required for seven beds for the proposed use. Show the location of these motor vehicle parking spaces on the revised set of plans. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 05/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/02/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |