Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.4
Permit Number - TC-COM-0323-00756
Review Name: COMMERCIAL REVIEW - FULL v.4
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/24/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/24/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Show how the hot water source will be located within 24” of the new lavatory. [Second comment: The source of hot water shall be no further than 24” from the termination of the hot water pipe serving the lavatory if ½” supply piping is used.]Show [Initial comment: Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018.] | ||
05/18/2023 | PDSD Application Completeness | REVIEW COMPLETED |