Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0323-00752
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/22/2023 | Commercial Structural | NOT REQUIRED | |||
04/04/2023 | Site Engineering | NOT REQUIRED | |||
04/22/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
04/05/2023 | Site Landscape | REQUIRES RESUBMIT | PROJECT: ECHO RIDGE COOPERATIVE ACTIVITY NO. TC-COM-0323-00752 ADDRESS/PARCEL: 8030 E BROADWAY BL: BLDG B UNIT 101/134-12-0090 ZONING: 0-3 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TSM) Section for landscape, native plants and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments are addressed. COMMENTS: 1. See Zoning Comments. 2. Either provide the NPPO Plan or Submit an NPPO waiver with site photos. Or remove it from the sheet index. 3. Revise the irrigation sheet (L.2) so the new trees do not obscure the rest of the plan. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
||
04/03/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0323-00752 8030 E Broadway Bl. – O-3 (1st Review) 7’ Site Wall w/ Landscape (1st Review) TRANSMITTAL: April 03, 2023 This site is located in O-3 (UDC Article 4.7.15). Multifamily is a permitted use in the zone (UDC Table 4.8-3). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. 2. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) Show the required street perimeter yard setback on the required Development Package. Street perimeter yard setbacks for Broadway Bl are based on UDC Article 6.4.5.C.2. Additional comments may be forth coming. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
03/15/2023 | Fire New Construction | REVIEW COMPLETED | |||
03/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |