Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0226-00291
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2026 Commercial Electrical Standard APPROVED
03/25/2026 Site Zoning Standard APPROVED
03/24/2026 Commercial Mechanical Standard NOT REQUIRED No mechanical work
03/24/2026 Commercial Plumbing Standard NOT REQUIRED No plumbing work
03/20/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
03/17/2026 Site Engineering Standard NOT REQUIRED
03/24/2026 Water - PDSD Standard NOT REQUIRED
03/25/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/24/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov

1. Please provide signed and sealed structural design, construction drawings and calculations, prepared by an Arizona licensed registrant, to be used in the design of this project. IBC 107.2.7

2. Please specify all the materials and their strengths used in this repair. IBC 107.2.1 For example, FAST SET NON-SHRINK STRUCTURAL GROUT
PATCH

3. Please provide a project specific statement of special inspections for this project, stating requirements for the special inspections and required tests. IBC 107.2.1, IBC 1704, IBC 1705

Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B
completed with the next submittal. IBC 107.1 SI form link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf



Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
03/25/2026 Fire New Construction Standard REVIEW COMPLETED
03/04/2026 PDSD Application Completeness Express REVIEW COMPLETED