Permit Number: TC-COM-0226-00258
Parcel: 133369690

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0226-00258
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2026 Site Zoning APPROVED
03/12/2026 Water - PDSD APPROVED
02/27/2026 Site Engineering NOT REQUIRED
03/16/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/16/2026 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please amend the plans to update the list of adopted applicable codes. IBC 107.2.1 For example,
2024 International Building Code (IBC)
2024 International Residential Code (IRC)
2024 International Existing Building Code (IEBC)
2017 ICC A117.1 Accessibility Code (by reference)
2024 International Mechanical Code (IMC)
2024 International Plumbing Code (IPC)
2023 National Electrical Code (NEC)
2024 International Fire Code (IFC)
2024 International Fuel Gas (IFGC)
2018 International Energy Conservation Code (IECC)
City of Tucson/Pima County Outdoor Lighting Code
Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes )
2. Please amend the Sheet Index to include all the drawing sheets in this permit’s scope. IBC 107.2.1
3. Please provide a floor plan with all spaces labeled with a name or description to convey the intended use of the space. IBC 302.1 For example, what is the area behind the counter? And the Retail area?
4. Amend the plans to provide the occupancy classifications, and occupant load factors for each space and area. IBC 302, IBC 1004.5
5. Please amend the plans to provide a legible Exiting/Egress plan. Include the number of occupants in each space or area. IBC 107.2.3
6. It appears the design occupant load could be above 49. Please provide a second exit that is available to all occupants. IBC 1006.1
7. Please amend the plans to provide the required drinking fountain. IBC 2902.1
8. Please amend the plans to provide the plumbing fixture calculations to determine the number of water closets and restrooms required for the occupant load. IBC 2902.1
9. IEBC 306.7 requires that accessibility be provided to the altered spaces. Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. Accessibility upgrades shall be required in accordance with IEBC.306.7. 1. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs. For example, the lavatory is encroaching in the 5’ clear space for water closet. 2017 ICC A117.1 604.3




Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
03/09/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0226-00258 (60 N HARRISON RD Unit:UNIT 140 TUCSON, AZ 85748)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Reference Sheet D1.0 and Sheet ‘4 of 7’ Reflected Ceiling Plan. Sheet D1.0 notes that the lighting fixtures shall be replaced with new fixtures. Sheet ‘4 0f 7’ shows the lighting fixtures being removed completely and only a few new lighting fixtures being added in new locations. Please clarify and show consistency in notes and documents.
2. Provide complete compliance with the 2018 IECC for the interior lighting, including sensors and lighting controls as required. (typically COMcheck).
3. Provide a lighting fixture schedule. Label the lighting fixtures on the schedule and on the new reflected ceiling plan.
03/12/2026 Commercial Mechanical REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0226-00258
ADDRESS/PARCEL: 60 N HARRISON RD Unit:UNIT 140 TUCSON, AZ 85748

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. The occupant load for this space has increased to 44 occupants. Please provide mechanical ventilation calculations demonstrating that the existing ventilation system is capable of supplying the minimum required outdoor air for this space. Reference: Section 403.3.1.1, IMC 2024.
03/12/2026 Commercial Plumbing REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0226-00258
ADDRESS/PARCEL: 60 N HARRISON RD Unit:UNIT 140 TUCSON, AZ 85748

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Demo floor plan shows the bathroom sink will be replaced. Please show there is a metering faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10 seconds. Reference: Section 412.13, IPC 2024, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09.
2. Please show the required service sink on the floor plans. Reference: Section 107.2.1, IBC 2024.
3. Provide a drinking fountain in accordance with the minimum plumbing fixture requirements of the code. The drinking fountain located in the existing Albertsons does not satisfy this requirement. Revise the plans to indicate a code-compliant drinking fountain or water dispenser. (IBC 2024, Section 2902)
03/13/2026 Fire New Construction REVIEW COMPLETED
02/27/2026 PDSD Application Completeness Express REVIEW COMPLETED