Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0226-00248
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/26/2026 | Site Engineering | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Design Review | PENDING ASSIGNMENT | |||
| 03/12/2026 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov Please provide dimensioned construction drawings and details showing how the folding operable window and the countertop are to be installed. IBC 107.2.1 Please provide a section through the new operable window and countertop with construction details. IBC 107.2.1 Please amend plans to indicate if safety glazing is being used, specify the U-factor and SHGC. IBC 107.2.1 Please amend the plans to show height of the new countertop meets 2017 ICC A117.1 Chapter 9 requirements. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 03/04/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0226-00248 (316 E CONGRESS ST TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov Plans shall include (as necessary for scope of work), but may not be limited to items below: 1. Provide an electrical plan showing the location of all demo’ed, modified or new electrical equipment, outlets, lighting fixtures, etc. Are there new lighting fixtures being added to properly illuminate the bar surface? 2. Show all wiring methods in detail for all new electrical conductors and branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 3. Provide a panel schedule, showing all circuits that are added, removed or modified. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. 4. Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixtures, receptacles, gate operator, equipment disconnect switch, etc., NEC arts;300 and 408.4. IBC 107.1. Each electrical outlet should be labeled by panel and circuit number. Additional comments may be forthcoming with complete electrical plans for the proposed site and electrical work. |
||
| 03/11/2026 | Historic | REQUIRES RESUBMIT | Revise elevation drawings. Need a window schedule and the window sill must match the sill heights of the other storefronts. | ||
| 03/10/2026 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-COM-0226-00248 316 E. Congress St. Tucson, AZ 85701 Replace Existing Windows and Install New Outdoor Bar (1st Review) TRANSMITTAL DATE: 3/10/2026 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the OCR-2 zone (UDC 4.7.27). 1. Comment: Plans call out a new folding window system and a solid surface countertop. Please clarify if there is outdoor seating proposed with this renovation. Also, please clarify what types of food/beverages will be served through this window and associated countertop. A Development Package may be required depending on responses to zoning comments. 2. Comment: As this site is located within the COT Rio Nuevo Area (RNA), RNA review must be completed and approved prior to zoning approval of this building permit. Please contact Maria Gayosso at Maria.Gayosso@tucsonaz.gov if you have questions about the RNA review process. Site Zoning cannot approve this permit until the RNA review has been approved. Additional information about RNA requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/planning-amp-zoning/rna-application-and-review-process.pdf. 3. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 03/10/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 02/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |