Permit Number: TC-COM-0226-00222
Parcel: 128010040

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0226-00222
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2026 Commercial Electrical Standard APPROVED
04/28/2026 Outdoor Lighting Standard APPROVED
04/24/2026 Site Engineering Standard APPROVED
05/11/2026 Water - PDSD Standard APPROVED
05/13/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/22/2026 Addressing Validation REQUIRES RESUBMIT If you have any questions about this review, please contact us at CDRC@tucsonaz.gov
The project address on this permit application does not match the project address on the plans submitted. Some of the documents submitted also list unit 110, others list unit 150. Please update documents and plans and resubmit. If the permit application lists the incorrect address, please submit a change of address.
How to request a change of address:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf
Step-by-Step instructions on how to resubmit plans: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
- address change has been processed and location on permit application is now Unit 150. Please just ensure all files match this in future submittals.
05/13/2026 Commercial Plumbing Standard REQUIRES RESUBMIT 1. Provide the delivery pressure setting for the existing pressure regulator to ensure a minimum pressure of 7” WG to each appliance. [Initial comment: State the minimum gas pressure required for each appliance by the appliance manufacturer. Reference: Section 402.1, IFGC 2024.]
2. The gas riser diagram only shows lengths for some of the sections of pipe. Show the developed pipe length from the regulator to each appliance. [Initial comment: Provide natural gas pipe sizing calculations. Include gas pressures and developed pipe lengths (from the meter or regulator to the appliance) on plans. Reference: Section 402.3, IFGC 2024.]

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
05/13/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0226-00222 - TD-DEV-0325-00090
5950 E. Broadway Blvd. Unit 150 Tucson, AZ 85711
TI (2nd Review)

TRANSMITTAL DATE: 5/13/2026

This site is located in the C-2 zone (UDC 4.7.21). Food Service with Alcoholic Beverage Service is a permitted use.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The associated Development Package (TD-DEV-0325-00090) is in an active revision. Please ensure the heights, square footage, and site improvements are identical to what is approved in the associated DP. Site Zoning is unable to approve this permit until the revised DP has been approved by all reviewers.
2. Comment: Additional comments may be forthcoming on the next review based on the proposed use and any applicable use specific standards.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
04/22/2026 PDSD Application Completeness Express REVIEW COMPLETED