Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0226-00151
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2026 | Commercial Mechanical Standard | APPROVED | |||
| 07/16/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2026 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0226-00151 ADDRESS/PARCEL: (1265 S SWAN RD TUCSON, AZ 85711) TC-COM-0526-00787 (3002 E GRANT RD Unit:UNIT 2 TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. WATER DISPENSER PROPOSED LOCATION AT THE HALL/ADMIN/OFFICE CORNER (note: NO WATER LINE AVAILABLE IMMEDIATELY NEAR TO DISPENSER) a. Where the Building and Plumbing Codes require a drinking fountain, the City of Tucson will accept point of use water dispenser in lieu of the classically recognized drinking fountain. b. The water dispenser must be listed and labeled in accordance with the Code. c. The water dispenser must be connected to a permanent supply of potable water. d. The water supply must be indicated on the plans and installed per code. e. A clear floor space shall be provided for the cooler in compliance with chapter 6 of ICC A117.1. f. A permanently mounted disposable cup dispenser shall be installed adjacent to the cooler with the dispensing end between 34" and 48" above finish floor and show the clear floor space complying to chapter 3 ICC A117.1 section 602.4. g. NOTE: waste line shall also be necessary to be connected to this drinking fountain h. Please correct this. 2. SHEET 2 FIXTURE SCHEDULE a. Bath/Shower b. Add the note: Appeal to the Building Official to remove this requirement. 3. Thank You for locating the Lit Exit Signs (ensure Battery Backup is present) and Fire Extinguishers in the Electrical Plan. a. However, Emergency Lights with Battery Backup are not shown on the plan. Please add them to the plan. 4. A new Certificate of Occupancy is required for a Child Day Care Facility. a. Please provide a complete Code Analysis to include (None of the items listed below are present within the site plan): i. Occupancy Group type I-4 Child Day Care ii. Construction Type of the building iii. Total Area of the building. iv. Fire Sprinkler 1. Please add a note referring to Exception #2 for Group I-4 Child Day Care. 5. NOTE: Site Plan and Parking Plan (Sheet 1 and 1a) were not submitted with this latest submission. Please submit them with the corrections requested above along with the rest of the sheets. 6. Please resubmit |
||
| 07/16/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0226-00151 ADDRESS/PARCEL: 1265 S SWAN RD TUCSON, AZ 85711 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: Plumbing 1. Please revise the plans to show how the approved water dispenser, located in the hallway, is permanently connected to the building's water distribution system. Point-of-use water dispensers are permitted in lieu of traditional drinking fountains only when connected to a permanent potable water supply. See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf |
||
| 07/16/2026 | Fire New Construction Standard | REQUIRES RESUBMIT | -The installation of a fire alarm needs to be mentioned on the drawings. Include the information in the code analysis. -Resolve all building comments. john.vincent@tucsonaz.gov 5203495581 |
||
| 07/13/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0226-00151 1265 S. Swan Rd. Tucson, AZ 85711 As Built Child Daycare (2nd Review) TRANSMITTAL DATE: 7/13/2026 The site is located in C-2 zone (UDC 4.7.21). Daycare is a permitted use in this zone (UDC Table 4.8-4). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Follow up to previous comment 1: The comment response letter provided states a Development Package will be applied for to address the offsite parking and associated PAAL’s. Our records indicate this Development Package has not been applied for as of this review date. Site Zoning is unable to approve this permit until the Development Package has been approved or the previous comment has been addressed. Please demonstrate compliance with UDC 7.4.6.B.1.b, which states the proposed offsite parking location has parking in excess of the minimum required parking for its use. Please include the adjacent parcels existing use and associated parking calculations. 2. Comment: Follow up to previous comment 2: The comment response letter provided states a Development Package will be applied for to address the offsite parking and associated PAAL’s. Our records indicate this Development Package has not been applied for as of this review date. Site Zoning is unable to approve this permit until the Development Package has been approved or the previous comment has been addressed. Please demonstrate compliance with UDC 7.4.6.B.1.e, which states the offsite parking area meets the design criteria provided in this section (ie: dimension the parking stalls and associated PAAL). 3. Comment: Follow up to previous comment 3: The comment response letter provided states a Development Package will be applied for in order to provide the lot combination approval. Our records indicate this Development Package has not been applied for as of this review date. Site Zoning is unable to approve this permit until the Development Package has been approved or the previous comment has been addressed. As this site is made up of two (2) parcels (13101053D and 13101055D), please provide an approved lot combination request form or a recorded Covenant Regarding Development and Use of Real Property with your next submittal. Contact Pima County for the lot combo request or the Covenant can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/covenant-regarding-development-and-use-of-real-property-udc-with-release.pdf. 4. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||