Permit Number: TC-COM-0225-00389
Parcel: 11703180A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL REVISION v.1

Permit Number - TC-COM-0225-00389
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2026 Commercial Building Standard APPROVED
04/28/2026 Commercial Electrical Standard APPROVED
04/27/2026 Commercial Plumbing Standard APPROVED
04/22/2026 Site Zoning Standard APPROVED
04/27/2026 Water - PDSD Standard APPROVED
04/20/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
04/09/2026 Site Engineering Standard NOT REQUIRED
04/30/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/27/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0225-00389
ADDRESS/PARCEL: 325 W 2ND ST Unit:BLDG 1 TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. The plans indicate that the kitchen area is divided into three separate spaces, with doors shown between them. Please clarify how air is being transferred between these spaces and how the design avoids using egress routes as a duct? Reference: Section 601.2, IMC 2018.
2. In Kitchen Tenant Space (130), the plans indicate approximately 2550 CFM at the return grille, while only 300 CFM is being supplied to the space. The amount of return air taken from any space shall not exceed the amount of supply air delivered to that space. Please revise or clarify. Reference: Section 601.5(3), IMC 2018.
04/30/2026 Fire New Construction Standard REVIEW COMPLETED
04/09/2026 PDSD Application Completeness Express REVIEW COMPLETED