Permit Number: TC-COM-0225-00386
Parcel: 10707003Q

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0225-00386
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/16/2025 Commercial Building Standard REQUIRES RESUBMIT April 16, 2025
2nd Review

CMA LLC
Attn: Chuck Meyer
11598 W. Rock Village Street
Tucson, Arizona 85658

Re: EARTHS HEALING INFUSION KITCHEN
TENANT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0225-00386
Stantec Project Number: 185215066
Stantec File Number: TUC-25-028

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
F-1 III-B 665 4 Yes No
Separate Permits: Automatic fire sprinklers, kitchen hood suppression system.
Deferred Submittals: None.
Special Inspections: None.

GENERAL COMMENTS

1. Addressed.

2. New Comment: The 2nd submittal did not include the structural calculations. All documents must be reuploaded with each new submittal. Please ensure that all documents are reuploaded with the next submittal. This should include the following: Construction documents, structural calculations, response letter, supplemental email.

ARCHITECTURAL COMMENTS

General

1. Addressed.

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

General

1. Addressed.

PLUMBING COMMENTS

General

1. Previous Comment: Please provide updated water pressure calculations with the added fixtures. [Ref. IPC 2018 Sec. 604] Still Required: The water pressure calculations were submitted with the response letter. These calculations must be included in the plumbing set of the construction drawings.

2. Addressed.

Sheet P121

1. Addressed.

2. Addressed.

3. Addressed.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/16/2025 Commercial Electrical Standard REQUIRES RESUBMIT April 16, 2025
2nd Review

CMA LLC
Attn: Chuck Meyer
11598 W. Rock Village Street
Tucson, Arizona 85658

Re: EARTHS HEALING INFUSION KITCHEN
TENANT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0225-00386
Stantec Project Number: 185215066
Stantec File Number: TUC-25-028

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
F-1 III-B 665 4 Yes No
Separate Permits: Automatic fire sprinklers, kitchen hood suppression system.
Deferred Submittals: None.
Special Inspections: None.

GENERAL COMMENTS

1. Addressed.

2. New Comment: The 2nd submittal did not include the structural calculations. All documents must be reuploaded with each new submittal. Please ensure that all documents are reuploaded with the next submittal. This should include the following: Construction documents, structural calculations, response letter, supplemental email.

ARCHITECTURAL COMMENTS

General

1. Addressed.

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

General

1. Addressed.

PLUMBING COMMENTS

General

1. Previous Comment: Please provide updated water pressure calculations with the added fixtures. [Ref. IPC 2018 Sec. 604] Still Required: The water pressure calculations were submitted with the response letter. These calculations must be included in the plumbing set of the construction drawings.

2. Addressed.

Sheet P121

1. Addressed.

2. Addressed.

3. Addressed.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/16/2025 Commercial Mechanical Standard REQUIRES RESUBMIT April 16, 2025
2nd Review

CMA LLC
Attn: Chuck Meyer
11598 W. Rock Village Street
Tucson, Arizona 85658

Re: EARTHS HEALING INFUSION KITCHEN
TENANT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0225-00386
Stantec Project Number: 185215066
Stantec File Number: TUC-25-028

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
F-1 III-B 665 4 Yes No
Separate Permits: Automatic fire sprinklers, kitchen hood suppression system.
Deferred Submittals: None.
Special Inspections: None.

GENERAL COMMENTS

1. Addressed.

2. New Comment: The 2nd submittal did not include the structural calculations. All documents must be reuploaded with each new submittal. Please ensure that all documents are reuploaded with the next submittal. This should include the following: Construction documents, structural calculations, response letter, supplemental email.

ARCHITECTURAL COMMENTS

General

1. Addressed.

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

General

1. Addressed.

PLUMBING COMMENTS

General

1. Previous Comment: Please provide updated water pressure calculations with the added fixtures. [Ref. IPC 2018 Sec. 604] Still Required: The water pressure calculations were submitted with the response letter. These calculations must be included in the plumbing set of the construction drawings.

2. Addressed.

Sheet P121

1. Addressed.

2. Addressed.

3. Addressed.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/30/2025 Commercial Mechanical Standard REQUIRES RESUBMIT ODOR MITIGATION REQUESTED BY ZONING
The manufacturer’s literature for the RGF QRP-9 Guardian Photohydroionization cell unit addresses its use in HVAC systems but not exhaust ducts from Type II hoods. Provide installation instructions from the manufacturer for this application along with supporting data attesting to the effectiveness of the unit to mitigate odors in this application. Show how the exhaust for existing hood is being addressed. [Initial comment: The current mechanical design does not provide any form of the required odor mitigation. Reference: City of Tucson Ordinance 11828 Sec. 4.9.9.E.1.I.]
04/16/2025 Commercial Plumbing Standard REQUIRES RESUBMIT April 16, 2025
2nd Review

CMA LLC
Attn: Chuck Meyer
11598 W. Rock Village Street
Tucson, Arizona 85658

Re: EARTHS HEALING INFUSION KITCHEN
TENANT IMPROVEMENT

City of Tucson Permit Number: TC-COM-0225-00386
Stantec Project Number: 185215066
Stantec File Number: TUC-25-028

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
F-1 III-B 665 4 Yes No
Separate Permits: Automatic fire sprinklers, kitchen hood suppression system.
Deferred Submittals: None.
Special Inspections: None.

GENERAL COMMENTS

1. Addressed.

2. New Comment: The 2nd submittal did not include the structural calculations. All documents must be reuploaded with each new submittal. Please ensure that all documents are reuploaded with the next submittal. This should include the following: Construction documents, structural calculations, response letter, supplemental email.

ARCHITECTURAL COMMENTS

General

1. Addressed.

STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

General

1. Addressed.

PLUMBING COMMENTS

General

1. Previous Comment: Please provide updated water pressure calculations with the added fixtures. [Ref. IPC 2018 Sec. 604] Still Required: The water pressure calculations were submitted with the response letter. These calculations must be included in the plumbing set of the construction drawings.

2. Addressed.

Sheet P121

1. Addressed.

2. Addressed.

3. Addressed.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
04/30/2025 Site Zoning Standard REQUIRES RESUBMIT 1. COMMENT: Please address City of Tucson Commercial Mechanical comment regarding the Odor Mitigation systems.

Demonstrate compliance with applicable use specific standard, UDC 4.9.9.E.1.I - Odor mitigation devices and techniques shall be incorporated in all marijuana facilities to ensure that odors are mitigated. As such, this may be done through an exhaust air filtration system with odor control that prevents internal odors from being emitted externally or through any other best practices deemed adequate for odor mitigation as determined by the Zoning Administrator.

An odor mitigation plan shall be submitted demonstrating compliance with odor control requirement.

Loran Shamis
Loran.Shamis@tucsonaz.gov
04/09/2025 PDSD Application Completeness Express REVIEW COMPLETED