Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.3
Permit Number - TC-COM-0225-00381
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/05/2025 | Commercial Plumbing Fast | REQUIRES RESUBMIT | 1. Drawing P-1 has not been sealed. [Second comment: Seal drawing sheet P1.0. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.] 2. Comment not addressed. Show a detail of the connection to the 2” horizontal branch after the penetration of the wall at keynote 2. [Second comment: Provide a detail showing the connection of the effluent of the sump pump to the sanitary drain system as described in Section 712.3.5, IPC 2018. Reference: Section 712.1, IPC 2018. 3. A flowrate of 13 GPM (26 DFU) in a 2” pipe requires ½” slope. State the required slope on the drawing. [Second comment: Revise the size of the building sub-drain per Table 710.1(1), IPC 2018. Reference: Section 709.3, IPC 2018. 4. A horizontal branch may connect 10 pipe diameters (20”) downstream of the base of the stack, Section 704.3, IPC 2018. [Second comment: Clarify keynote #1 on sheet P1.0 regarding the connection of the new sub-drain to the existing drainage system. Reference: Section 107.2.1, IBC 2018. [Initial comment: The submitted documents do not adequately show the scope of work for this address or how any intended changes will comply with the adopted building codes. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.] |
||
| 04/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |