Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0225-00357
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/11/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/11/2025 | Commercial Building | REQUIRES RESUBMIT | For questions in regards to plan review comments, please contact Bill McClellan by email at bmcclellan@willdan.com or cell (928)580-3179. 1. Sheet A-1 List all adopted building codes on plans for design to include mechanical, plumbing, energy and electrical. Incomplete. 2018 IBC 107.2.1 (BM) 2. Building codes should be identified and noted with amendments, plan notes (City of Tucson IBC local amendments) [ Ver. 2 ] [Edited By Bill McClellan] |
||
| 04/11/2025 | Commercial Electrical | REQUIRES RESUBMIT | 1. Sheet E-1 Will need to provide or identify maintenance receptacle for both AH & CU location to comply with 2017 NEC 210.63 (BM) | ||
| 04/11/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Not address. Same for new AH-1 location in ceiling. See electrical requirements for equipment in attic 2. Sheet MP-1 Mechanical system revised design with AH-1 unit in attic now requires an attic access and opening to comply with 2018 IMC 306.3 & 306.3.1 (BM) Note: Plan notes #5, #6 & 21 on sheet A-2 identify 5/8" drywall ceiling on a dropped framed ceiling Note: Will need to provide structural analysis for AH-1 to be supported by existing trusses or joists [ Ver. 5 ] [Edited By Bill McClellan] |
||