Permit Number: TC-COM-0225-00355
Parcel: 10702012A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0225-00355
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/06/2025 Commercial Electrical Standard APPROVED
05/27/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/23/2025 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Original comments restated
1. Please address the previous stated review comment - (Prior to approving the electrical plans, we will need building plans and the use of the proposed building. Please provide a complete set of plans in accordance with SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements, a Complete set of fully dimensioned plans demonstrating the full scope of work shall be provided. All plans must be sealed and signed by an Architect or Engineer registered in the State of Arizona. Note. The term “building plans” may refer to structural, electrical, plumbing, or any other trade regulated by the associated suite of codes adopted by the City of Tucson.
Commercial Submittal requirements Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf )
NEW COMMENT FROM SECOND REVIEW 5/23/2025
2. TZ-PMT-0325-00013 is a temporary use permit for Zoning purposes that has not been approved as yet. However, that permit only allows temporary use. A separate building permit would be required for construction.
3. Any structure that is erected for a period of 180 days or more must comply with other sections of the code applicable to permanent structures. It should be noted that “temporary” refers to the structure being erected, not the use of the structure; therefore, if a structure is erected for 365 days a year, but is used on a seasonal basis for less than 180 days, this section does not apply. Such structures are considered permanent. It should also be noted that membrane structures, even those erected for less than 180 days, are subject to standards applicable to permanent buildings where they are attached to such buildings IBC 3103.1
4. This structure would appear to be a Mixed Construction type and require compliance with IBC section 3102 in general and IBC 3102.6 specifically.
Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
05/27/2025 Site Zoning Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-COM-0225-00355
3178 N FREEWAY INDUSTRIAL LP. - I-1
Electrical service entrance and interior power/lighting for a pre-manufactured building. (2nd Review)

TRANSMITTAL DATE: ‎May 23, 2025

This comment was not addressed. COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the I-1 zone (UDC 4.7.29). Proposed use unknown.

1. This comment was not addressed. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
05/02/2025 PDSD Application Completeness Express REVIEW COMPLETED