Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0225-00325
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2025 | Commercial Mechanical Standard | APPROVED | |||
| 03/13/2025 | Site Zoning Standard | APPROVED | |||
| 03/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/14/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please amend the plans to provide construction drawings detailing the connection of the coiling overhead doors to the existing exterior walls. Additionally, provide sealed structural design and calculations, attachment method and list any required special inspections. IBC 107.2.7 2. Please provide the special inspection certificate with Part A, and Part B, completed with next submittal. IBC 107.2.1 If required. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 03/06/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0225-00325 (3160 E TRANSCON WY TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Clarify the scope of electrical work. The one-line diagram shows two new panels, CC1 and CC2 along with new feeders from PNL ‘H’. Also clarify the provided panel schedule which is for panel ‘A1’ but appears should be labeled PNL ‘H’ to match the line diagram. 2. Provide updated panel schedules for the two new panels and the existing panel PNL ‘L’, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. Clearly mark existing loads/circuits and those being modified or added to. 3. Designate the circuit number, that corresponds to the panel schedule, at the location of each new or modified light fixture, receptacle, appliance, and equipment disconnect switch, NEC arts;300 and 408.4. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/27/2025 | Fire New Construction Standard | REQUIRES RESUBMIT | Under Code Analysis data: 1. Remove the 2012 IFC and add the 2024 IFC with local amendments. 2. Check the 2024 requirements for the proposed project. 3. sal.erivezjr@tucson.gov |
||
| 02/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |