Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0225-00286
Parcel: 11452008H

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0225-00286
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT Master Set of Plans on TC-COM-0824-01552/(6) 4-Bay carports with reviews to be conducted for TC-COM-0225-00286/(10) 6-Bay carports and TC-COM-0225-00287/(4) 8-Bay carports
02/28/2025 Commercial Building Standard REQUIRES RESUBMIT Master Set of Plans on TC-COM-0824-01552/(6) 4-Bay carports with reviews to be conducted for TC-COM-0225-00286/(10) 6-Bay carports and TC-COM-0225-00287/(4) 8-Bay carports
Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved.
1. Please submit a separate application for permit for each canopy. For example,
TC-COM-0824-01552 will be used for one 4-bay and (5) more permits will be required for all (6) 4-bay structures. Please refer to TC-COM-824-01552 Master Permit
TC-COM-0225-00286 will be used for one 6-bay and (9) more permits will be required for all (10) 4-bay structures. Please refer to TC-COM-824-01552 Master Permit
TC-COM-0225-00287 will be used for one 8-bay and (3) more permits will be required for all (4) 4-bay structures. Please refer to TC-COM-824-01552 Master Permit
2. With each permit - Please provide a site plan with each canopy uniquely identified. IBC 107.2.1 For example, A,B,C…
3. With each permit - Please provide the special inspection certificate with Part A, and Part B, completed with next submittal. IBC 107.2.1 FYI-The EOR has listed three special inspections on SheetS1.1 - Fabricators, Cold-Formed Steel Framing and Structural Steel
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf

Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
03/13/2025 Site Engineering Standard REQUIRES RESUBMIT TC-COM-0225-00286
9125 E CATALINA HY

See zoning comments

Chris Arrington chris.arrington@tucsonaz.gov


Master Set of Plans on TC-COM-0824-01552/(6) 4-Bay carports with reviews to be conducted for TC-COM-0225-00286/(10) 6-Bay carports and TC-COM-0225-00287/(4) 8-Bay carports
02/26/2025 Site Zoning Standard REQUIRES RESUBMIT Master Set of Plans on TC-COM-0824-01552/(6) 4-Bay carports with reviews to be conducted for TC-COM-0225-00286/(10) 6-Bay carports and TC-COM-0225-00287/(4) 8-Bay carports

FROM: PDSD Zoning Review

PROJECT: TC-COM-0824-01552, TC-COM-0225-00286 & TC-COM-0225-00287
9125 E CATALINA HY. – Multifamily – R-2
Parking structure- Shade Canopy (2nd Review)

TRANSMITTAL DATE: February 26, 2025

Resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standard 4.9.7.B.6, .9, & .10.

1. This comment was not addressed. Provide a copy of the approved DP sheets that clearly indicates which covered parking structures you are permitting. Provide a copy of the approved development package sheet that clearly shows where the proposed shade structure is located. This sheet shall be the stamped approved sheet.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/12/2025 PDSD Application Completeness Express REVIEW COMPLETED