Review Status: Approved

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0224-00384
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
03/25/2024 External Reviewers - Willdan APPROVED Ed Kulik ekulik@willdan.com
1. Sheet A1.0 Will the 1st floor unit be made into Type A Units? Has this been discussed with the COT? It appears you are upgrading the MPE to the current code.
2. Sheet A1.0 Provide a thermal expansion tank at water heater P2903.4.1.
3. Sheet M1.0 Provide a secondary condensate line per M1411.3.
4. Sheet E1.0 Provide GFCI Outlet at Peninsular per E3901.4.3.
04/02/2024 Site Zoning APPROVED
04/01/2024 Site Engineering NOT REQUIRED
04/02/2024 Bldg Permits - Post Review Express REVIEW COMPLETED
03/04/2024 Fire New Construction REVIEW COMPLETED
03/01/2024 PDSD Application Completeness Express REVIEW COMPLETED