Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0224-00373
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/27/2024 | Commercial Electrical | APPROVED | |||
04/02/2024 | Site Zoning | APPROVED | |||
04/01/2024 | Site Engineering | NOT REQUIRED | |||
04/02/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/02/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Provide a Type I grease hood over the induction range. Reference: Section 507.2.1, IMC 2018. 2. Show that the heat and moisture loads from the proposed glass washing machine are included in the HVAC load calculations for the space or install a Type II hood over the glass washing machine. Reference: Section 507.3, IMC 2018. |
||
04/02/2024 | Commercial Plumbing | REQUIRES RESUBMIT | Clarify the reason for reducing the size of the CW line from 1” to ¾”after the branch to the ice machine and before the branch to the water heater which is increased to 1”. Reference: Section 107.2.1, IBC 2018. | ||
04/02/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Sheet A1: Please amend plans to provide a detailed description of the work involved in this permit’s scope. IBC 105.3 For example: This tenant improvement scope includes combining two existing shell suites for a new Delicatessen. Interior work shall include the removal of a portion of an existing demising wall to allow for a new kitchen, eating area and inside sales. The existing store front double door in Suite 186 will be removed and the opening filled in with store front system. 2. Sheet A1: Please amend plans to reference the shell permit number in plan set for 1st Tenant Improvement. IBC 107.2.1 & COT Commercial submittal requirements 3. Sheet A1: Please amend plans to add IEBC 2018 (International Existing Building Code) to note #1 under general notes IBC 107.2.1 4. Sheet A1: Please amend plans to describe the number of stories in the building as well as the story this project is located on. IBC 107.2.1 5. Sheet A1: Please consider changing the occupancy classification of the entire floor area as A-2 or if the occupant load is under 50 it can be classified as B. IBC 303.1.1. Otherwise, provide the method of separation used between the different occupancies. Additionally, the M occupancy group doesn’t appear to match the actual use. IBC 508 and IBC 302 6. Sheet A4: Please amend plans to show the fire resistive rating for the walls separating the tenant spaces from adjacent tenant space(s). Typically, this would be shown on shell permit construction drawings and be a 1-hour wall. IBC 508.4 7. Sheet A4: Please amend the plans to show the maneuvering clearance required by 2009 ICC A117.1 at the rear door leading to the restrooms as this will likely require the seating to be altered. 2009 ICC A117.1 404.2 Keep in mind that a latch and closer will be additive to the dimensions shown in Table 404.2.3.2 8. Sheet A4: Please calculate the occupant load using 18” per person for the Banquette per IBC 1004.6 |
||
03/25/2024 | Fire New Construction | REVIEW COMPLETED | |||
03/01/2024 | PDSD Application Completeness | REVIEW COMPLETED |