Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0224-00307
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/15/2024 | Site Engineering | APPROVED | |||
11/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
11/04/2024 | Commercial Electrical | REQUIRES RESUBMIT | November 4, 2024 1st Review A23 Studios Attn: Burak Bekat 711 E. 9th Street Tucson, Arizona 85719 Re: MISTER CARWASH CRAYCROFT NEW BUILDING (REVISIONS) City of Tucson Permit Number: TC-COM-0224-00307 Stantec Project Number: 185215066 Stantec File Number: TUC-24-135 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 5,402 22 No No Separate Permits: Signage, pre-engineered canopy and trellis. Deferred Submittals: Pre-engineered wood trusses, pre-engineered canopies, pre-engineered awning and trellis. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, masonry, EFIS, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. Please clarify on the cover page that the sperate permit indicated for site utilities is specifically for private site sewer including any requirement for a backwater valve. Sheet A1.0 1. Please revise comment 44 to clarify that the civil plans with the site sewer construction will be applied for separately. STRUCTURAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the engineer of record. Sheet S1.3 1. Please provide a site plan indicating the specific locations of the vacuum footings with a shade canopy and without a shade canopy. The architectural site plan does not show any canopies for the vacuums to differentiate the footing locations. MECHANICAL COMMENTS Sheet M1.0 1. The detail call-out for the drip pan of SAF-1 is incorrect. Please revise this to reflect the correct detail on Sheet M2.0. 2. Please revise the duct call-out for SAF-1 on the First Floor Plan from “EA UP” to “SA UP” as the ducting is supplying air from the supply air fan. PLUMBING COMMENTS Sheet P1.0 1. Please indicate on this sheet to clarify that the site utilities presented are diagrammatic only as the site sewer will be applied for under a separate permit. The original approved plan-set was red lined to reflect that the site sewer presented on this sheet was not approved because the site sewer is under a separate permit. 2. The cleanout indicated at the sewer line coming from Keynote 8 is not allowed. Cleanouts shall enable cleaning of drainage piping in the direction of drainage flow. [Ref. IPC 2018 Sec. 708.1.8] Sheet P2.0 1. Please provide a label for the grade clean-out on the underground plan. [Ref. IPC 2018 Sec. 708.1.3] ELECTRICAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the structural engineer of record. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
11/04/2024 | Commercial Mechanical | REQUIRES RESUBMIT | November 4, 2024 1st Review A23 Studios Attn: Burak Bekat 711 E. 9th Street Tucson, Arizona 85719 Re: MISTER CARWASH CRAYCROFT NEW BUILDING (REVISIONS) City of Tucson Permit Number: TC-COM-0224-00307 Stantec Project Number: 185215066 Stantec File Number: TUC-24-135 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 5,402 22 No No Separate Permits: Signage, pre-engineered canopy and trellis. Deferred Submittals: Pre-engineered wood trusses, pre-engineered canopies, pre-engineered awning and trellis. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, masonry, EFIS, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. Please clarify on the cover page that the sperate permit indicated for site utilities is specifically for private site sewer including any requirement for a backwater valve. Sheet A1.0 1. Please revise comment 44 to clarify that the civil plans with the site sewer construction will be applied for separately. STRUCTURAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the engineer of record. Sheet S1.3 1. Please provide a site plan indicating the specific locations of the vacuum footings with a shade canopy and without a shade canopy. The architectural site plan does not show any canopies for the vacuums to differentiate the footing locations. MECHANICAL COMMENTS Sheet M1.0 1. The detail call-out for the drip pan of SAF-1 is incorrect. Please revise this to reflect the correct detail on Sheet M2.0. 2. Please revise the duct call-out for SAF-1 on the First Floor Plan from “EA UP” to “SA UP” as the ducting is supplying air from the supply air fan. PLUMBING COMMENTS Sheet P1.0 1. Please indicate on this sheet to clarify that the site utilities presented are diagrammatic only as the site sewer will be applied for under a separate permit. The original approved plan-set was red lined to reflect that the site sewer presented on this sheet was not approved because the site sewer is under a separate permit. 2. The cleanout indicated at the sewer line coming from Keynote 8 is not allowed. Cleanouts shall enable cleaning of drainage piping in the direction of drainage flow. [Ref. IPC 2018 Sec. 708.1.8] Sheet P2.0 1. Please provide a label for the grade clean-out on the underground plan. [Ref. IPC 2018 Sec. 708.1.3] ELECTRICAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the structural engineer of record. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
11/04/2024 | Commercial Plumbing | REQUIRES RESUBMIT | November 4, 2024 1st Review A23 Studios Attn: Burak Bekat 711 E. 9th Street Tucson, Arizona 85719 Re: MISTER CARWASH CRAYCROFT NEW BUILDING (REVISIONS) City of Tucson Permit Number: TC-COM-0224-00307 Stantec Project Number: 185215066 Stantec File Number: TUC-24-135 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 5,402 22 No No Separate Permits: Signage, pre-engineered canopy and trellis. Deferred Submittals: Pre-engineered wood trusses, pre-engineered canopies, pre-engineered awning and trellis. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, masonry, EFIS, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. Please clarify on the cover page that the sperate permit indicated for site utilities is specifically for private site sewer including any requirement for a backwater valve. Sheet A1.0 1. Please revise comment 44 to clarify that the civil plans with the site sewer construction will be applied for separately. STRUCTURAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the engineer of record. Sheet S1.3 1. Please provide a site plan indicating the specific locations of the vacuum footings with a shade canopy and without a shade canopy. The architectural site plan does not show any canopies for the vacuums to differentiate the footing locations. MECHANICAL COMMENTS Sheet M1.0 1. The detail call-out for the drip pan of SAF-1 is incorrect. Please revise this to reflect the correct detail on Sheet M2.0. 2. Please revise the duct call-out for SAF-1 on the First Floor Plan from “EA UP” to “SA UP” as the ducting is supplying air from the supply air fan. PLUMBING COMMENTS Sheet P1.0 1. Please indicate on this sheet to clarify that the site utilities presented are diagrammatic only as the site sewer will be applied for under a separate permit. The original approved plan-set was red lined to reflect that the site sewer presented on this sheet was not approved because the site sewer is under a separate permit. 2. The cleanout indicated at the sewer line coming from Keynote 8 is not allowed. Cleanouts shall enable cleaning of drainage piping in the direction of drainage flow. [Ref. IPC 2018 Sec. 708.1.8] Sheet P2.0 1. Please provide a label for the grade clean-out on the underground plan. [Ref. IPC 2018 Sec. 708.1.3] ELECTRICAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the structural engineer of record. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
11/04/2024 | Commercial Structural | REQUIRES RESUBMIT | November 4, 2024 1st Review A23 Studios Attn: Burak Bekat 711 E. 9th Street Tucson, Arizona 85719 Re: MISTER CARWASH CRAYCROFT NEW BUILDING (REVISIONS) City of Tucson Permit Number: TC-COM-0224-00307 Stantec Project Number: 185215066 Stantec File Number: TUC-24-135 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 5,402 22 No No Separate Permits: Signage, pre-engineered canopy and trellis. Deferred Submittals: Pre-engineered wood trusses, pre-engineered canopies, pre-engineered awning and trellis. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, masonry, EFIS, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. Please clarify on the cover page that the sperate permit indicated for site utilities is specifically for private site sewer including any requirement for a backwater valve. Sheet A1.0 1. Please revise comment 44 to clarify that the civil plans with the site sewer construction will be applied for separately. STRUCTURAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the engineer of record. Sheet S1.3 1. Please provide a site plan indicating the specific locations of the vacuum footings with a shade canopy and without a shade canopy. The architectural site plan does not show any canopies for the vacuums to differentiate the footing locations. MECHANICAL COMMENTS Sheet M1.0 1. The detail call-out for the drip pan of SAF-1 is incorrect. Please revise this to reflect the correct detail on Sheet M2.0. 2. Please revise the duct call-out for SAF-1 on the First Floor Plan from “EA UP” to “SA UP” as the ducting is supplying air from the supply air fan. PLUMBING COMMENTS Sheet P1.0 1. Please indicate on this sheet to clarify that the site utilities presented are diagrammatic only as the site sewer will be applied for under a separate permit. The original approved plan-set was red lined to reflect that the site sewer presented on this sheet was not approved because the site sewer is under a separate permit. 2. The cleanout indicated at the sewer line coming from Keynote 8 is not allowed. Cleanouts shall enable cleaning of drainage piping in the direction of drainage flow. [Ref. IPC 2018 Sec. 708.1.8] Sheet P2.0 1. Please provide a label for the grade clean-out on the underground plan. [Ref. IPC 2018 Sec. 708.1.3] ELECTRICAL COMMENTS General 1. Please include the light pole footing design in the structural plan-set as this is addressed by the structural engineer of record. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
11/22/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0224-00307 - TD-DEV-0224-00042 5515 E Grant Rd. - C-2 New Car Wash (Revision 3, 1st Review) TRANSMITTAL DATE: November 22, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Automotive Service and Repair - Automotive Washing - Self Service is a permitted use in the zone (UDC Table 4.8-4). 1. COMMENT: Zoning has reviewed the building plan for compliance with TD-DEV-0224-00042, and although it appears that the plans match, Zoning cannot approve the building plans until the revision to the DP is approved by all review agencies. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
11/12/2024 | Fire New Construction | REVIEW COMPLETED | |||
10/30/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |