Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.3
Permit Number - TC-COM-0224-00278
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/15/2024 | Site Zoning | APPROVED | |||
| 02/27/2024 | Site Engineering | NOT REQUIRED | |||
| 03/04/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/04/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0224-00278 ADDRESS/PARCEL: (5214 E PIMA ST Unit:BLDG 3 TUCSON, AZ 85712) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Additional information is required. 2. What type of Mercantile entity is your client. Are they a clothing store, jewelry store, a bodega, etc. What do they sell, do they carry soft drinks, liquor, perishable foods, hot dogs, etc? 3. On the Floor Plan, show the equipment, shelving, display cases, cashier (provide drawings that illustrates the ANSI A117.1 requirement for this cashier counter). 4. With the layout from item #3 above (the display layout)..…will additional lights required or existing be moved, etc. If so, provide electrical drawing. 5. Submit a Reflected Ceiling Plan illustrating item #4 above as well as air diffusers, return air, lighted exit sign, emergency light with battery backup, etc 6. On the Floor Plan show all existing electrical receptacles. 7. This structure is sharing wall with the structure on the other side of the properly line, provide drawing illustrating the assembly that complies to the fire rating required as well as the fire rating for portion of the structure that is within 3 feet from the property line. 8. NOTE: there will be inspections conducted, the above drawings will be crucial to be able to do those inspections including fire inspection. This will be required in order to issue a new Certificate of Occupancy. 9. Please re-submit. |
||
| 02/26/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/14/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |