Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0224-00245
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/27/2024 | Site Zoning | APPROVED | |||
03/12/2024 | Water - PDSD | APPROVED | |||
02/29/2024 | Site Engineering | NOT REQUIRED | |||
03/14/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/14/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | February 9, 2024 1st Review Joesler Village Tucson, LLC Attn: Karen Wolf 555 E. River Road, Suite 201 Tucson, Arizona 85704 Re: TUCSON, ARIZONA 85704 PSOMAS - REMODEL City of Tucson Permit Number: TC-COM-0224-00245 Stantec Project Number: 185215066 Stantec File Number: TUC-24-011 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 11,450 76 Yes No Separate Permits: Automatic fire sprinklers. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Please indicate that the automatic fire sprinkler system modification [2018 IBC Sec. 903] is to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS General 1. Please provide energy conservation compliance reports for the new mechanical units indicated. [Ref. IECC 2018 C403.3.2] Sheet M-4 1. The outside air ventilation calculations table is missing the “IT Room” O.A. ventilation calculations. [IMC 2018 Table 403.3.1.1] PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS Sheet E4.0 1. The one-line diagram and panel schedules have conflicting information for Panels P, P1, P2, and M. The one-line indicates that the panels are all MCB, but the panel schedules show them as MLO. Please clarify and revise. [Ref. NEC 2017 Art. 240] 2. The one-line diagram and panel schedules have conflicting information for Panel P. The one-line diagram indicates Panel P with a 400-amp bus and the panel schedule indicates the panel as 200-amp. Please clarify and revise. 3. The fault current calculations and panel schedules have conflicting information for panels P, P1, P2, and M. The fault current calculations indicate the AIC rating of the panels as 42,000 but the panel schedules indicate the AIC rating as 22,000. Please clarify and revise. 4. The feeder schedule is missing feeders for Panel P2. Please revise. 5. Please indicate the fault current analysis marks on the one-line diagram. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
02/29/2024 | Fire New Construction | REVIEW COMPLETED | |||
02/06/2024 | PDSD Application Completeness | REVIEW COMPLETED |