Permit Number: TC-COM-0224-00231
Parcel: 13705565C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0224-00231
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/21/2024 Commercial Plumbing APPROVED
02/05/2024 Site Zoning APPROVED
02/21/2024 Water - PDSD APPROVED
02/09/2024 Site Engineering NOT REQUIRED
02/21/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
02/20/2024 Commercial Building REQUIRES RESUBMIT Project number: TC-COM-0224-00231 (4734 S LANDING WY Unit:110 TUCSON, AZ 85714)
Permit description: Tenant Improvement for European Wax Center
Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed.
1. Sheet T1: Please amend Building Data-Previous Use to show the Shell permit number for first Tenant Improvement. SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements. For example, T22CM03468
2. Sheet T1: Please amend Building Data-Proposed Occupancy to reflect B- Business (Professional Services) use in place of M IBC 304.1
3. Sheet A5.0: Please amend plans to shows interior wall and ceiling finishes are classified for fire and smoke. IBC 803.1
4. Sheet A2.0: Please amend plan to show drinking fountain location, or the travel distance to the drinking fountain. Alternatively, when a single drinking fountain is required, it may be substituted with a point of use water cooler or dispenser. 410.4 IPC as amended by the City of Tucson.

Mark Masek
Plans Examiner
Mark.masek@tucsonaz.gov
520-837-4994
02/15/2024 Commercial Electrical REQUIRES RESUBMIT Please address the electrical plan review comments and provide a written response.
Provide compliance with the 2018 IECC for the lighting. ComCheck ie acceptable.
Ref; 2018 IECC
02/21/2024 Commercial Mechanical REQUIRES RESUBMIT The Building Data on sheet T1 states that the proposed use for this suite is, “European Wax Center Beauty Salon Use.” The ventilation calculations on sheet M1.0 base the ventilation requirements for the wax rooms on the beauty salon requirements (20 CFM per person and 0.12 CFM per square foot) without the mandatory exhaust of 0.6 CFM per square foot and the limiting requirements of footnote b, Table 403.3.1.1, IMC 2018. Provide an engineering analysis of the ventilation requirements for the wax center that justifies this approach. Reference: Section 403.3.1.1, IMC 2018.
02/08/2024 Fire New Construction REVIEW COMPLETED
02/02/2024 PDSD Application Completeness REVIEW COMPLETED