Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0223-00707
Parcel: 117080930

Address:
804 S 6TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0223-00707
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
07/31/2023 Commercial Building REQUIRES RESUBMIT Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed.
1. CMU walls using 8" x 8" x 16 " blocks requires a minimum of 24 " wide footing (you show 16") and bottom of footing requires minimum of 18" below finish grade (you show 12"). Please correct your Masonry Wall drawings.
2. Typical sidewalks are 4" thick (you show 12"), please re-verify.
3. Provide Footing detail for the 2"x2" square tubing post into existing concrete slab. Provide detail drawing that will support a 6 feet wide swimming gate to be hung on this 2"x2" post. You may find that this post size will not be sufficient.
4. Please re-submit.
07/05/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0223-00707
804 S 6th Av. –C-3
Site wall & gates (2nd Review)

TRANSMITTAL: July 05, 2023
This site is located in C-3 zone (UDC 4.7.22). General Merchandise Sales is a permitted use in the zone (UDC Table 4.8-4).

1. This comment was not addressed. The required DP is a separate submittal. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://cms3.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/28/2023 PDSD Application Completeness REVIEW COMPLETED