Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0223-00672
Parcel: 135084450

Address:
1345 S KOLB RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0223-00672
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/05/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
03/27/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Activity Number: TC-COM-0223-00672

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Provide Structural Calculations for Foundations, Columns and Roof Framing for both Ramada’s per Section 1601.1 of International Building Code 2018. Specify all Structural Member Sizes including Foundations, Columns and Roof Framing Members on the Floor/Roof Plans.
2. Provide Wind Load Calculations for the Ramada’s per Section 1609 of International Building Code 2018.
3. Provide Seismic Calculations for the Ramada’s per Section 1613 of International Building Code 2018.
4. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018.
5. Provide Geotechnical Report per International Building Code 2018, Section 1803.1.
Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings.


BUILDING REVIEW COMMENTS:
Approved


MECHANICAL REVIEW COMMENTS:
N/A


ELECTRICAL REVIEW COMMENTS
N/A


PLUMBING REVIEW COMMENTS:
N/A


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
04/03/2023 Site Engineering REQUIRES RESUBMIT See zoning comments
03/31/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TD-DEV-0223-00672
1395 S Kolb Rd. – C-2
Ramadas (1st Review)

TRANSMITTAL: March 31, 2023
This site is located in C-2 Zone (UDC 4.7.21), M is a permitted use in the zone, (Table 4.8-4).

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. As DP22-0211 is still active a revision to the DP showing the proposed changes needs to be submitted and approved prior to approval of this building permit.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/05/2023 Fire New Construction REVIEW COMPLETED
03/10/2023 PDSD Application Completeness REVIEW COMPLETED