Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0223-00667
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/02/2023 | Historic | NOT REQUIRED | |||
| 04/02/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/23/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0223-00667 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: Denied 1. Sheet TS: The occupant load for the tap room is calculated incorrectly. It appears that there is fixed seating (booths or benches) present and should be calculated appropriately. Provide a corrected occupant land in accordance with Section 1004.6. 2. At least 5% of the dining surfaces including that bar are required to have mobility features. Provide calculations of the required amount of accessible seating and indicate the locations. Additionally, ensure that surfaces are properly dispersed throughout the structure. Section 226.1 and 226.2 of the 2010 ADAAG. MECHANICAL REVIEW COMMENTS: Denied 1. Provide a detailed kitchen equipment schedule. 2. Provide all manufacturer specifications for the pizza oven for review. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: BLDG #2 1). Show roof drain conductor sizes on plan page P1.0. -IPC 1106.2 (only shows roof drain sizes) 2). Show the accessible route with distances to the plumbing restrooms that will serve this building. -IPC 3). Plan page P1.0 Detail #1 states water & Gas plan, no gas system is shown? -IFGC 106.3.1 4). BLDG #2 Hose Bibs on plan page P1.0 need shut off valves-IPC 606.2 5). Bldg. #2 needs a service sink -IPC 403.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 03/24/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comments | ||
| 03/22/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0223-00667 1000 W Congress St. – C-1 (1st Review) TRANSMITTAL: March 22, 2023, 2023 This site is located in C-1 zone (UDC 4.7.20). Food Service is a permitted use in the zone, (Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Zoning has reviewed the plan for compliance with development package (DP) TD-DEV-1222-00074 but until the DP has been approved by all review agencies Zoning cannot approve this plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/23/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 03/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |