Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0223-00643
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/03/2023 | Site Engineering | NOT REQUIRED | |||
04/03/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
03/23/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0223-00643 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. 2018 IBC 107.2.1. Revise sheet G1.2 - Detail 3 to include the depth of the footing and depth of bollard embedment. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied1. 2018 IBC 107.2.1. Clarification needed. Sheet A1.1 "Equipment Schedule" indicates that Q01## - Remote Condensing Unit is to be installed on the dining room roof; however, there is no information regarding this equipment and it does not clearly show on the floor plans. Provide the equipment specifications and location on the plans, or if it is not being used, eliminate the item from the schedule ELECTRICAL REVIEW COMMENTS Denied 1. 2018 IBC 107.2.1. Revise the electrical floor plans to show electrical circuitry, including the panel name and circuit number, that each outlet/appliance/equipment is connected to. 2. 2018 IBC 1008.3.2. Revise the plans to show emergency lighting on the exterior of the building at the landing for egress doors. 3. 2017 NEC 700.12(F)(2)(3). Revise the plans to indicate the emergency lighting units will be tied to the local lighting circuit, ahead of any switching devices. PLUMBING REVIEW COMMENTS: Denied 1. 2018 IPC - 608.1. Revise the plans to indicate the backflow prevention device for the beverage systems. 2. 2018 IPC - 1002.4. Revise the plans to include a trapped floor drain (if none exists) for the new drink stations, as referenced on sheet A1.1 - note #14. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
03/29/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0223-00643 5391 E SPEEDWAY BL Zoning C-2 TRANSMITTAL DATE:March 29, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Clarify if signage is being proposed with this permit, If signage is not being proposed provide a not that “signs are by separate permit” If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
03/20/2023 | Fire New Construction | REVIEW COMPLETED | |||
03/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |