Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0223-00635
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/05/2023 | Site Zoning | APPROVED | |||
03/29/2023 | Site Engineering | NOT REQUIRED | |||
04/05/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/23/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0223-00635 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. 2018 IBC - Table 601. Clarification needed on construction type. and/or plans revised. Sheet G003 code data indicates type II-A construction type. Partition type "A" surrounds a primary structural column in the "Sales Area"; however, there is no fire resistance-rated designation as required for type II-A construction primary members. Verify if II-A construction is correct and revise the partition type; or, revise the construction type to be compliant with Table 601. 2. 2018 IBC - 1109.9 & 2009 ANSI A-117.1. Revise the plans to show that 5% of the storage lockers are accessible, and the hardware does not require a pinching or twisting motion. 3. 2018 IBC - 107.2.1. Revise the code data to include whether a fire alarm system is installed. 4. 2018 IBC - 107.2.1. Revise sheet A503 to eliminate the penetration details that are not relevant to this project. MECHANICAL REVIEW COMMENTS: Denied 1. 2018 IMC - 307.2.1, 307.2.2. Revise the plans to show the size and routing of the condensate drain piping. ELECTRICAL REVIEW COMMENTS Denied 1. 2018 IBC - 1008.3. Revise the plans to indicate that the emergency lights will have a remote head located on the exterior of the building, at each egress door. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov Activity Number: TC-COM-0223-00635 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. 2018 IBC - Table 601. Clarification needed on construction type. and/or plans revised. Sheet G003 code data indicates type II-A construction type. Partition type "A" surrounds a primary structural column in the "Sales Area"; however, there is no fire resistance-rated designation as required for type II-A construction primary members. Verify if II-A construction is correct and revise the partition type; or, revise the construction type to be compliant with Table 601. 2. 2018 IBC - 1109.9 & 2009 ANSI A-117.1. Revise the plans to show that 5% of the storage lockers are accessible, and the hardware does not require a pinching or twisting motion. 3. 2018 IBC - 107.2.1. Revise the code data to include whether a fire alarm system is installed. 4. 2018 IBC - 107.2.1. Revise sheet A503 to eliminate the penetration details that are not relevant to this project. MECHANICAL REVIEW COMMENTS: Denied 1. 2018 IMC - 307.2.1, 307.2.2. Revise the plans to show the size and routing of the condensate drain piping. ELECTRICAL REVIEW COMMENTS Denied 1. 2018 IBC - 1008.3. Revise the plans to indicate that the emergency lights will have a remote head located on the exterior of the building, at each egress door. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
03/27/2023 | Fire New Construction | REVIEW COMPLETED | |||
03/09/2023 | PDSD Application Completeness | REVIEW COMPLETED |